5. Troubleshooting
8
Problem Cause Remedy
≠ Motor does not start > Plugofmainsleadnot
inserted
> Fuse of mains plug sok-
ket has blown
> Overload protection
switch has tripped
Insert main lead plug
into plug socket
Reset the fuse
Allow the cleaner to cool
down for approx. 5 mi-
nutes; if the cleaner does
not start again automati-
cally, contact the Service
Dept.
≠ Motor does not run in
automatic mode
> Electric tool defective or
not properly connected
Check function of elec-
tric tool or push in plug
rmly
≠ No suction power during
wet cleaning
> Tank full (oat switch
closing o the suction
opening)
Empty tank
≠ Reduced suction power
> Bag-type lter full
> Suction hose clogged
> Filter element clogged
Replace bag-type lter
Clean suction hose
Clean or replace lter
element