Do you have a question about the Renishaw OLP40 and is the answer not in the manual?
Type | Optical probe |
---|---|
Compatibility | Compatible with Renishaw optical receivers |
Repeatability | 1.0 µm (0.00004 in) 2σ |
Transmission method | Infrared |
Modulation | Modulated optical |
Battery type | 2 x AA alkaline |
Storage Temperature | -10 °C to 70 °C (14 °F to 158 °F) |
Power Supply | Battery powered |
Illustrates inserting the stylus into the probe body.
Shows tightening the stylus with a torque wrench.
Explains LED flashes and color codes for settings.
Details probe switch-off timers and trigger filter configuration.
Explains settings for legacy and modulated probe optical transmission.
Details options for low, standard, and ultra-low optical power.
Shows how battery status is indicated by LED patterns.
Explains using stylus deflection to move through settings menus.
Illustrates how battery status is displayed when changing settings.
Visualizes the sequence of selections for probe switch-off methods.
Visualizes the sequence of selections for the trigger filter.
Visualizes the sequence of selections for optical transmission.
Visualizes the sequence of selections for optical power levels.
Illustrates securing the probe to the shank using hex screws.
Shows tightening the shank screws with a torque wrench.
Details the process for adjusting stylus on-centre alignment in the X axis.
Details the process for adjusting stylus on-centre alignment in the Y axis.
Illustrates securing the stylus after on-centre adjustment.
Explains LEDs for system, start, battery, probe status, signal, and errors.
Explains LEDs for probes, start, battery, signal, and errors on OMI units.
Provides legal disclaimers and lists registered trade marks.
Details warranty exclusions and China RoHS information.
States EU conformity and provides WEEE disposal guidance.
Provides information regarding substances of very high concern (SVHCs).
Details FCC compliance statements and user cautions for USA.
Outlines critical safety rules for handling and using the OLP40.
Provides essential guidelines for battery handling, safety, and proper disposal.
Defines responsibilities for user safety awareness and protective measures.
Provides installation guidelines for EU and FCC regulatory compliance.
Covers operation precautions and LED optical safety.