EasyManuals Logo

Renishaw OMP60 User Manual

Renishaw OMP60
115 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #9 background imageLoading...
Page #9 background image
1-7
Battery status
Battery good
or
Battery low
Enhanced trigger filter setting
Off
0 s
or
On
10 ms
or
On
20 ms
or
On
40 ms
Optical transmission method
Legacy
(start filter off)
or
Legacy
(start filter on)
or
Modulated
Optical power
Low
or
Standard
Probe in standby mode (after 5 seconds)
Reviewing the probes settings

Other manuals for Renishaw OMP60

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Renishaw OMP60 and is the answer not in the manual?

Renishaw OMP60 Specifications

General IconGeneral
Transmission TypeOptical
SealingIPX8
Transmission MethodOptical
Protection RatingIPX8
TypeOptical transmission probe
Probe CompatibilityOMI-2
Measurement Range60 mm
DimensionsDiameter 63 mm
Stylus Trigger Force0.75 N typical