Reno
A
&
E
4655
Aircenter
Circle
Reno,
Nevada
89502
U.S.A.
Engineering
Excellence!
Telephone;
(775)
826-2020
Facsimile:
(775)826-9191
Internet:
www.renoae.com
E-mail:
contact@renoae.com
MODEL
"B"
SERIES
Single
Channel
Loop
Detectors
OPERATING
INSTRUCTIONS
Indicators
PWR
Power
LED
STATUS
MEANING
Off
On
No
power
or
low
power
to
detector
Normal
power
to
detector
If
the
supply
voltage
drops
below
75%
of
the
nominal
line
voltage,
the
power
LED
will
turn
"off."
This
provides
a
visual
check
of
low
line
voltage
that
can
be
caused
by
the
start
up
of
a
gate
motor.
The
Model
B
operates
with
line
voltage
as
low
as
85
VAC.
DET
Detect
LED
STATUS
MEANING
Off
Solid
On
4
Hz
Flashing
No
vehicle
present
over
loop
Vehicle
present
over
loop
Vehicle
present
over
loop
for
less
than
2
seconds
(2
Sec.
Delay)
FAIL
Failed
loop
LED
STATUS
MEANING
Off
Solid
On
1
Hz
Flashing,
50%
duty
cycle
1
Hz
Flashing,
5%
duty
cycle
Loop
OK
Open
loop
Shorted
loop
Waiting
for
release
of
FREQ
switch
to
enter
diagnostics
mode
Front
Panel
Switches
(Momentary")
FREQ
Selects
one
of
four
loop
frequencies:
(HIGH
/
MH
/
ML
/
LOW).
(Also
used
to
enter
loop
diagnostics
mode).
RESET
Resets
the
detector
to
the
"No
Call",
i.e.
no
vehicle
detected
state.