Description of the
PLT
®
Solas
By opening the closing valve, air ows from the air cylinder through the
Reduction Valve and into the chamber of the Base Unit. The pressure in this
chamber is 75 bars (1088 psi).
Due to heavy recoil, it is important that the PLT
®
Solas is well supported
during operation. The rear end of the PLT
®
Solas Launching Unit has a
Damper Pad that must be placed against a solid point that can withstands
this force. See page 9.
The air cylinder must be lled to a minimum of 207 bar (3000 psi) for a
minimum of 4 launches. With 300 bar (4350 psi) the unit can perform a
minimum of 6 launches.
The air cylinder rells from a 207/300 bar air compressor for breathing air
systems. If you are using a 207-bar compressor, the Yoke Adaptor, Art. No.
1308 is necessary to use.
Launching unit:
Weight/Length 7,5 kg / 65 cm (16.5lb / 25.5 in)
Color Orange
Materials Anodized Aluminum, Stainless Steel
Chamber Pressure 75 bar (1088 psi)
Estimated Recoil Force 5300 N
Air cylinder:
Pressure 207/300 bar (3000/4350 psi)
Volume 1500 cm3 (91 in3)
Coupling Standard 5/8” BA-Coupling DIN 477
Practical Information
Contact Information
Restech Norway
Postal Address
P.O. Box 624
N-8001, Bodø (Bodoe)
Norway
Ofce Number
+47 755 42 440
Visiting Address
Olav V Gate 112
8004 Bodø (Bodoe)
Norway
E-mail
restech@restech.no
For more information
www.restech.no
Product Certicates
Notifying Body: DNV GL Type Approval
MED-B Certicate
Type Approval USCG
Type Approval Transport Canada