Changes
47
5 Changes
Change index “C”
05.748.0101 main board for the frequency converter 02.199.0005 has been changed
Main board fuse 0.16A T changed to 0.25A T, VDR resistance eliminated
03.105.0342 frequency converter cable 02.199.0005 changed
1 VDR resistance inserted into each of all 3 wires
Change index “D”
05.748.0101 frequency converter main board changed
The control has been given an additional capacitor
Change index “F”
A partition wall has been added, retrofit kit 22.823.0009
Change index “G”
Motor changed, now 02.441.0399
Change index “H”
The cable 03.105.0342 changed, neutral and phase bridged with a VDR resistance
Firmware update to Version 1.52
Change index “I”
The Siei frequency converter assembly was replaced with the Fuji assembly
Please use the Retrofit kit 02.199.0008
See chapter 3.5 conversion of the frequency converter from Siei to Frenic-Mini
Change index “L”
Replacing the motor flange 03.443.0015
Replacing the labyrinth disc 02.706.0270
Replacing the sealing ring for the cartridge with foam rubber 03.114.0092
Change index “O”
Replacing back plane RS485 is no more longer necessary
Change index “P”
The main board GP was replaced with the GP2 control board
Please use the item number 05.748.0179
See chapter 3.3 Replacing the Control PCB GP2
Firmware update to version 4.01
Change index “Q”
The main board GP2 05.748.0179 was replaced with the GP2 board TFT 05.748.0193
Display TFT 02.569.0019 – display required GP2 board for TFT
Now free access to the main fuses on the backside of the ZM200
Firmware update GP2 board version V01.06
Firmware update TFT display version V01.04