EasyManua.ls Logo

Reversomatic RERV-S100 - User Manual

Default Icon
16 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
HRV / ERV INSTALLATION AND
OPERATING INSTRUCTIONS
Toll Free: 1.800.810.3473 (Canada)
1.866.890.6457 (U.S.A.)
790 Rowntree Dairy Road,
Woodbridge, ON Canada L4L 5V3
t: 905.851.6701
f: 905-851.8376
e: info@reversomatic.com
www.reversomatic.com
Maxum Series
model:
RHRV-S200A
Aluminum Core
RHRV-S200P
Polypropylene Core
RERV-S200
Enthalpy Core
Economy Series
model:
RHRV-E100A
Aluminum Core
RHRV-E100P
Polypropylene Core
RERV-E100
Enthalpy Core
Superior Series
model:
RHRV-S100A
Aluminum Core
RHRV-S100P
Polypropylene Core
RERV-S100
Enthalpy Core
C US
®
®
2100
CERTIFIED
Project Series
model:
RHRV-P100A
Aluminum Core
RHRV-P100P
Polypropylene Core
RERV-P100
Enthalpy Core

Questions and Answers

  • P
    Patrick ReyesAug 15, 2025
    How to improve low airflow in my Reversomatic RERV-S100?
    • M
      mhernandezAug 15, 2025
      Low airflow in your Reversomatic Furnace can stem from several causes. Here's what to check: * **Improperly balanced HRV/ERV airflow:** Have a professional balancer or contractor balance the unit. * **Clogged filter:** Remove and clean the filter. * **Obstructed core:** Remove and clean the core. * **Blocked exterior fresh air supply:** Remove the blockage. * **Closed damper:** Check the damper. * **Restricting ductwork:** Inspect the duct installation. * **Low power supply:** Switch off the unit immediately and call the electrician to check the voltage.
  • S
    smithabigailAug 18, 2025
    What to do if my Reversomatic RERV-S100 is not defrosting properly?
    • S
      Susan ThomasAug 19, 2025
      If your Reversomatic Furnace isn't defrosting correctly, consider these potential causes: * **Frozen fresh air duct:** Check for and remove any ice. * **Improperly balanced HRV/ERV airflow:** Have a professional balancer or contractor balance the unit. * **Defective temperature sensor:** Replace the temperature sensor.
  • J
    Jeremy FreemanAug 22, 2025
    Why is my Reversomatic Furnace sensing cold air from the supply?
    • C
      cohenheatherAug 22, 2025
      If your Reversomatic Furnace is sensing cold air from the supply, here are a few things to investigate: * **Blocked exhaust hood:** Remove any blockages and clean the hood outside the building. * **Improperly balanced HRV/ERV airflow:** Have a contractor balance the unit. * **Extremely cold outdoor temperature:** Consider installing a duct heater.
  • T
    Travis SchroederAug 26, 2025
    What does it mean when the LEDs on my Reversomatic RERV-S100 flash twice?
    • B
      Brandon BrowningAug 26, 2025
      If the LEDs on the Main Control board and the remote wall mount Timer Switch of your Reversomatic Furnace are flashing 0.5 sec On/0.5 sec Off/0.5 sec On then 2 sec Off, then repeat the cycle (2 Blinks), it could indicate: * **Obstructed damper:** Check the backdraft damper to ensure no screw interferes with its function. * **Exhaust fan jam/over-current:** Replace the fan.
  • D
    Duane JonesAug 29, 2025
    Why doesn't the timer light stay on for my Reversomatic Furnace?
    • C
      Cynthia StevensAug 29, 2025
      If the 20/40/60 minute light on your Reversomatic Furnace timer switch doesn't stay on, it might be due to: * **Loose connection:** Check the connection. * **Defective switch:** Replace the timer switch. * **Issue with main controller:** Reset the main controller.
  • A
    Andrew StanleySep 1, 2025
    What does it mean when the LEDs on my Reversomatic Furnace flash three times?
    • T
      Tristan LaneSep 1, 2025
      If the LEDs on the Main Control board and the remote wall mount Timer Switch of your Reversomatic Furnace are flashing 0.5 sec On/0.5 sec Off/0.5 sec On/0.5 sec Off/ 0.5 sec On, then 2 seconds Off, then repeat the cycle (3 Blinks), it indicates that the supply fan has an open circuit. This can be due to a burned motor or an overheated fan. Replace the motor.
  • L
    Laura DrakeSep 4, 2025
    What does it mean when the LEDs on my Reversomatic Furnace flash four times?
    • E
      elizabeth25Sep 4, 2025
      If the LEDs on the Main Control board and the remote wall mount Timer Switch of your Reversomatic Furnace are flashing 0.5 sec On/0.5 sec Off/0.5 sec On/0.5 sec Off/ 0.5 sec On/0.5 sec Off/0.5 sec On then 2 seconds Off, then repeat the cycle (4 Blinks), it could mean: * **Obstructed damper:** Check the back-draft damper, ensuring no screw interferes with its function. * **Supply fan jam/over-current:** Replace the fan.
  • S
    Shaun McclureSep 8, 2025
    What does it mean when the LEDs on my Reversomatic RERV-S100 Furnace flash once?
    • K
      kenneth32Sep 8, 2025
      If the LEDs on the Main Control board and the remote wall mount Timer Switch of your Reversomatic Furnace are flashing 0.5 second On then 2 seconds Off then repeat the cycle (1 Blink), it indicates an open circuit in the exhaust fan. This could be due to a burned motor or an overheated fan. Replace the motor.
  • N
    nealjuliaSep 12, 2025
    What does it mean when the LEDs on my Reversomatic Furnace flash five times?
    • E
      Emily OwenSep 12, 2025
      If the LEDs on the Main Control board and the remote wall mount Timer Switch of your Reversomatic Furnace flash 0.5 sec On/0.5 sec Off/ 0.5 sec On/0.5 sec Off/ 0.5 sec On/0.5 sec Off/ 0.5 sec On/0.5 sec Off/ 0.5 sec On/0.5 sec Off/ 0.5 sec On, then 2 seconds Off, then repeat the cycle (5 Blinks), it indicates a temperature sensor failure. In this case, both motors will shut off. Replace the temperature sensor.

Summary

Important Safety Instructions

General Safety Warnings

Covers precautions to reduce fire, electric shock, or injury, and general warnings for safe operation.

Wiring Diagram Overview

Furnace Interlock Wiring Diagrams

Typical HRV;ERV Installation Scenarios

Specific Installation Details

Air Flow Balancing Procedures

Balancing Procedure

Outlines the steps for achieving balanced air flows, ensuring proper HRV/ERV efficiency.

Pitot Tube Balancing Method

Describes using a Pitot tube and magnehelic gauge for field balancing airflow in ducts.

Maintenance Procedures

Annual Maintenance Procedures

Troubleshooting Common Issues

Air Flow and Cold Air Issues

Addresses low airflow, cold supply air, and water in the bottom of the unit with possible causes and solutions.

Unit Indicator and Performance Issues

Troubleshoots issues like unit not defrosting, LED blinks, and control board errors.

Troubleshooting Control and Timer Issues

Timer and Control Board Issues

Diagnoses problems with timer lights, LED patterns, and communication between control boards.

Reversomatic RERV-S100 Specifications

General IconGeneral
BrandReversomatic
ModelRERV-S100
CategoryFurnace
LanguageEnglish

Related product manuals