MAINSLINK-PRO
DS-MAINSLINKPRO-3
PATENT No 2564512
1. Apply a 230Vac supply to the first MAISNLINK-PRO
2. Briefly place a magnet across enclosure (Right side as
shown) to activate the internal reed switch.
3. The GREEN comms LED will flash 3 times to show in Pair-
ing Mode
Advanced OperationPairing together two MAINSLINK-PROs
NOTE: This system does not require pairing, they are supplied ready to operate!
This process is described for advanced use only.
Erasing a MAINSLINK-PRO
A
B
4. Apply 230Vac to the second MAINSLINK-PRO
5. Briefly place a magnet across enclosure (Right Side as
shown) to activate the internal reed switch.
6. The GREEN comms LED will flash 3 times to show in Pairing
Mode
7. The two MAINSLINK-PRO units which will now auto pair to-
gether (allow 30 secs -Green Comms LED will stay on.)
To erase the system hold a magnet beside Right Side of
the enclosure for 10 seconds as shown.
Repeat this process on both units to erase system.
Technical Specification:
Dimensions: 92 x 92 x 59mm
Electrical Characteristics Min Typical Max Units
Supply Voltage TX/RX: 100 230 250 Vac
Operating Frequency* 869.50 MHz
RF Output power +20 dBm
Bandwidth (Spreading Factor) 60 KHz
Maximum switching load (RX) 1000 W
Time delay from Tx Transmit to Rx Relay
operation:
Mode 3
Mode 7
3
4