EasyManuals Logo

Rheem 13AJM42A01 User Manual

Rheem 13AJM42A01
24 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #21 background imageLoading...
Page #21 background image
Rheem Heating, Cooling and Water Heating 21
Suction Line Length/Size versus Capacity Multiplier (R-410A)
Unit Size 1
1
/2 Ton 2 Ton 2
1
/2 Ton 3 Ton 3
1
/2 Ton 4 Ton 5 Ton
Suction Line
Connection Size
3/4" [19.05] I.D. 7/8" [22.23] I.D.
Suction Line Run—
Feet [m]
5
/8" [15.88 mm] O.D. Opt.
3
/4" [19.05 mm] O.D. Std.*
5
/8" [15.88 mm] O.D. Opt.
3
/4" [19.05 mm] O.D. Std.*
7
/8" [22.23 mm] O.D. Opt.
3
/4" [19.05 mm] O.D. Opt.
7
/8" [22.23 mm] O.D. Std.*
7
/8" [22.23 mm] O.D. Opt.
1
1
/8" [28.58 mm] O.D. Std.*
25' [7.62]
Optional
Standard
Optional
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
50' [15.24]
Optional
Standard
Optional
0.98
0.99
0.98
0.99
0.96
0.98
0.99
0.98
0.99
0.99
0.99
0.99
0.99
0.99
0.99
100' [30.48]
Optional
Standard
Optional
0.95
0.96
0.95
0.96
0.94
0.96
0.97
0.96
0.97
0.96
0.98
0.96
0.98
0.97
0.98
150' [45.72]
Optional
Standard
Optional
0.92
0.93
0.92
0.94
0.91
0.93
0.95
0.94
0.95
0.94
0.96
0.95
0.96
0.94
0.97
System
Capacity
Line Size
(Inch O.D.)
[mm]
Liquid Line Size – Outdoor Unit Above Indoor Coil
(Cooling Only—Does not apply to Heat Pumps)
Liquid Line Size – Outdoor Unit Below Indoor Coil
Minimum Vertical Separation—Feet [m] Maximum Vertical Separation—Feet [m]
25
[7.62]
50
[15.24]
75
[22.86]
100
[30.48]
125
[38.10]
150
[45.72]
25
[7.62]
50
[15.24]
75
[22.86]
100
[30.48]
125
[38.10]
150
[45.72]
Total Equivalent Length—Feet [m] Total Equivalent Length—Feet [m]
5/16* [7.94] 0 0 0 0 0 0 25 [7.62] 50 [15.24] 62 [18.90] 58 [17.68] 53 [16.15] 49 [14.94]
1
1
/2 Ton
1/4 [6.35] 0 0 0 0 8 [2.44] 24 [7.32] 25 [7.62] 40 [12.19] 25 [7.62] 9 [2.74] N/A N/A
3/8* [9.53] 0 0 0 0 0 0 25 [7.62] 50 [15.24] 75 [22.86] 72 [21.95] 70 [21.34] 68 [20.73]
3 Ton
5/16 [7.94] 0 0 0 0 0 9 [2.74] 25 [7.62] 50 [15.24] 37 [11.28] 22 [6.71] 7 [2.13] N/A
3/8* [9.53] 0 0 0 0 0 0 25 [7.62] 50 [15.24] 68 [20.73] 63 [19.20] 58 [17.68] 53 [16.15]
3
1
/2 Ton
5/16 [7.94] 0 0 0 16 [4.88] 35 [10.67] 54 [16.46] 25 [7.62] 23 [7.01] 4 [1.22] N/A N/A N/A
3/8* [9.53] 0 0 0 0 0 0 25 [7.62] 50 [15.24] 43 [13.11] 36 [10.97] 30 [9.14] 24 [7.32]
4 Ton
3/8* [9.53] 0 0 0 0 0 0 25 [7.62] 46 [14.02] 38 [11.58] 30 [9.14] 22 [6.71] 15 [4.57]
1/2 [12.57] 0 0 0 0 0 0 25 [7.62] 50 [15.24] 56 [17.07] 55 [16.76] 53 [16.15] 52 [15.85]
Liquid Line Sizing (R-410A)
5/16* [7.94] 0 0 0 0 0 0 25 [7.62] 49 [14.94] 38 [11.58] 27 [8.23] 17 [5.18] 6 [1.83]
2
1
/2 Ton
1/4 [6.35] 0 14 [4.27] 56 [17.07] 98 [29.87] N/A N/A 25 [7.62] N/A N/A N/A N/A N/A
3/8* [9.53] 0 0 0 0 0 0 25 [7.62] 50 [15.24] 68 [20.73] 65 [19.81] 62 [18.90] 58 [17.68]
5/16* [7.94] 0 0 0 0 0 0 25 [7.62] 36 [10.97] 29 [8.84] 23 [7.01] 16 [4.88] 9 [2.74]
2 Ton
1/4 [6.35] 0 3 [0.91] 29 [8.84] 55 [16.76] 81 [24.69] 108 [32.92] 23 [7.01] N/A N/A N/A N/A N/A
3/8* [9.53] 0 0 0 0 0 0 25 [7.62] 50 [15.24] 72 [21.95] 70 [21.34] 68 [20.73] 65 [19.81]
3/8
[9.53]
3/8
[9.53]
3/8
[9.53]
3/8
[9.53]
3/8
[9.53]
Liquid Line
Connection
Size
(Inch I.D.)
3/8
[9.53]
5 Ton
3/8* [9.53] 0 0 0 0 0 0 25 [7.62] 50 [15.24] 56 [17.07] 44 [13.41] 32 [9.75] 20 [6.10]
1/2 [12.57] 0 0 0 0 0 0 25 [7.62] 50 [15.24] 75 [22.86] 81 [24.69] 79 [24.08] 76 [23.16]
3/8
[9.53]
Condensing Unit Refrigerant Line Size Information
NOTES: *Standard line size
N/A = Application not recommended.
GENERAL TERMS OF LIMITED WARRANTY
Rheem will furnish a replacement for any part of this product
which fails in normal use and service within the applicable
period stated, in accordance with the terms of the limited
warranty.
*For Complete Details of the Limited Warranty, Including Applicable
Terms and Conditions, See Your Local Installer or visit www.Rheem.com.
Conditional Compressor*
(Registration Required)............................Ten (10) Years
Any Other Part ..........................................Five (5) Years
Conditional Parts* (Registration Required) ....Ten (10) Years
BEFORE PURCHASING THIS APPLIANCE, READ IMPORTANT ENERGY COST AND EFFICIENCY INFORMATION AVAILABLE
FROM YOUR RETAILER.
NOTES: *Standard line size
Using suction line larger than shown in chart will result in poor oil return and is not recommended.
[ ] Designates Metric Conversions

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rheem 13AJM42A01 and is the answer not in the manual?

Rheem 13AJM42A01 Specifications

General IconGeneral
BrandRheem
Model13AJM42A01
CategoryAir Conditioner
LanguageEnglish

Related product manuals