Type | Air Conditioner |
---|---|
SEER Rating | 13 |
Cooling Capacity | 36, 000 - 60, 000 BTU/h |
Tonnage | 3-5 Tons |
Refrigerant Type | R-410A |
Compressor Type | Scroll |
Operating Voltage | 208/230V |
Phase | 1 |
Sound Level (Outdoor Unit) | 74 dB |
Series | RKNL |
General specifications for the combination gas heating/electric cooling rooftop unit.
Lists the main components included in the unit.
Details about the R-410A refrigerant used in the unit, including specifications and safety.
Use only the approved type of gas for the unit, as indicated on the rating plate.
General installation requirements, referencing national and local codes.
Emphasizes that units are designed for outdoor installation only to ensure performance and safety.
Warns against connecting return ductwork to other heat devices due to fire/explosion risks.
Warns that circulating combustion products can cause hazardous conditions like CO poisoning.
Instructions for connecting the unit to the commercial gas utility supply.
Warning about hazardous voltage and the need for qualified service technicians.
Warns that conversion to LP gas requires a special kit to prevent fire or explosion.
Instructions for connecting the main electrical power supply and installing a branch circuit disconnect.
Warns to turn off electrical power before any wiring to prevent shock.
Details the step-by-step sequence of operations for the furnace ignition and heating cycle.
Warns against bypassing or resetting the control without addressing the cause, to prevent CO poisoning.
Warns that bypassing the limit control can cause fire or explosion.
Recommendations for the customer to ensure efficient and proper operation of the heating system.
Warns to label wires before disconnecting to prevent wiring errors causing dangerous operation.
Warns that holes in the heat exchanger can cause toxic fumes, leading to CO poisoning.
Warns to disconnect main electrical power before performing any cooling section maintenance.
Warns to label wires before disconnecting for servicing the unit's wiring.
Provides electrical specifications for various RKNL series models, including voltage, ampacity, and motor data.
Details blower motor speeds (Low, Med, High) and their corresponding performance data.
Details blower motor speeds (Low, Med, High) and their corresponding performance data.
Specifies the capacity and voltage range for 3-ton models.
System charge chart for 3-ton units using R-410A refrigerant, showing pressure relationships.
System charge chart for 3.5-ton units using R-410A refrigerant, showing pressure relationships.
System charge chart for 4-ton units using R-410A refrigerant, showing pressure relationships.
System charge chart for 5-ton, 13 SEER units using R-410A refrigerant.
System charge chart for 5-ton, 14 SEER units using R-410A refrigerant.
Warns to disconnect all power before servicing to prevent electrical shock and injury.
Warns about hazardous voltage during furnace servicing and the need for qualified technicians.