Field Conversions
OWAIRFL
HORIZONTAL LEFT / LEFT VENT
PARTS NEEDED:
HORIZONTAL LEFT / LEFT VENT
PARTS NEEDED:
HORIZONTAL LEFT / LEFT VENT
FROM CONVERSION KIT RXGY-CK
FROM PARTS BAG(PROVIDED WITH UNIT)
INTAKE COUPLING
W/NUT
FROM CONVERSION KIT RXGY-CK
PARTS NEEDED:
FROM PARTS BAG(PROVIDED WITH UNIT)
!
PARTS NEEDED FOR THIS CONVERSION REQUIRE ITEMS
FROM THE
YOU MUST HAVE THE PARTS OUTLINED BELOW BEFORE
PROCEEDING.
PARTS NEEDED:
(X3)
PARTS NEEDED FOR THIS CONVERSION REQUIRE ITEMS
FROM THE PARTS BAG AND CONVERSION KIT
YOU MUST HAVE THE PARTS OUTLINED BELOW BEFORE
PROCEEDING.
PARTS NEEDED FOR THIS CONVERSION REQUIRE ITEMS
AND CONVERSION KIT RXGY-CK.
YOU MUST HAVE THE PARTS OUTLINED BELOW BEFORE
1/2" VINYL
CAP (YELLOW)
TOOLS/MATERIALS NEEDED:
DRILL
1/8" DRILL BIT
PLIERS
1/4" HEX HEAD DRIVER
.559" CONDENSATE
TRAP DRAIN PLUG
VENT TUBING
TOOLS/MATERIALS NEEDED:
PLIERS
1/4" HEX HEAD DRIVER TUBING CUTTER
CONDENSATE
TRAP GASKET
1/4" BLACK
VENT TUBING
TOOLS/MATERIALS NEEDED:
TUBING CUTTER
CONDENSATE
TRAP GASKET
#8 X 1/2"
SCREW
1/2" DRAIN
HOSE E
1
NOTE: STEPS 1- 4 SHOWN WITH FURNACE IN AS SHIPPED CONDITION
NOTE: THESE CONVERSION INSTRUCTIONS ARE INTENTIONALLY GENERIC, SOME PARTS MAY BE DIFFERENT IN YOUR FURNACE
NOTE: STEPS 1- 4 SHOWN WITH FURNACE IN AS SHIPPED CONDITION
NOTE: THESE CONVERSION INSTRUCTIONS ARE INTENTIONALLY GENERIC, SOME PARTS MAY BE DIFFERENT IN YOUR FURNACE
2
INTAKE
COUPLING
NOTE: STEPS 1- 4 SHOWN WITH FURNACE IN AS SHIPPED CONDITION
NOTE: THESE CONVERSION INSTRUCTIONS ARE INTENTIONALLY GENERIC, SOME PARTS MAY BE DIFFERENT IN YOUR FURNACE
INSTALL
NOTE: THESE CONVERSION INSTRUCTIONS ARE INTENTIONALLY GENERIC, SOME PARTS MAY BE DIFFERENT IN YOUR FURNACE
2b
NOTE: THESE CONVERSION INSTRUCTIONS ARE INTENTIONALLY GENERIC, SOME PARTS MAY BE DIFFERENT IN YOUR FURNACE
1
FLUSH MOUNT
PLUG
(DISCARD)
2d
FLUSH MOUNT
VENT HOSE
(DISCARD)
HOSE “D”
(RETAIN)
.403 DRAIN
PLUG
(DISCARD)
2a
1/2” VINYL1/2” VINYL
CAP
2c
1 - REMOVE CONDENSATE TRAP AND HOSES.
(RETAIN HOSE D FOR LATER USE.)
(NOTE: TO REMOVE TRAP, REMOVE (2) SCREWS AND
PULL STRAIGHT OUT).
1 - REMOVE CONDENSATE TRAP AND HOSES.
(RETAIN HOSE D FOR LATER USE.)
(NOTE: TO REMOVE TRAP,
REMOVE (2) SCREWS AND
PULL STRAIGHT OUT).
2a - REMOVE .403" DRAIN PLUG FROM FLUE ELBOW - DISCARD.
2b - INSTALL INTAKE COUPLING IN TOP PLATE.
2c - INSTALL 1/2" VINYL CAP (YELLOW) IN INDUCER COUPLING AS SHOWN.
2d - REMOVE RECTANGLE FLUSH MOUNT PLUG FROM JACKET SIDE-DISCARD.
(INSTALL)
2a - REMOVE .403" DRAIN PLUG FROM FLUE ELBOW - DISCARD.
2b - INSTALL INTAKE COUPLING IN TOP PLATE.
2c - INSTALL 1/2" VINYL CAP (YELLOW) IN INDUCER COUPLING AS SHOWN.
2d - REMOVE RECTANGLE FLUSH MOUNT PLUG FROM JACKET SIDE-DISCARD.
CAP
(INSTALL)
2c - INSTALL 1/2" VINYL CAP (YELLOW) IN INDUCER COUPLING AS SHOWN.
2d - REMOVE RECTANGLE FLUSH MOUNT PLUG FROM JACKET SIDE-DISCARD.
ST-A1194-35-01