EasyManua.ls Logo

Rheem RA1630AJ1NB - Model Number Identification

Rheem RA1630AJ1NB
48 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
R
96 V A
70
2 3 17 M S A
Brand Series Motor Major Rev Input
BTU/HR
Stages Air Flow Cabinet
Width
Configuration Nox Minor Rev
Rheem
90 - 90 AFUE
92 - 92 AFUE
95 - 95 AFUE
96 - 96 AFUE
97 - 97 AFUE
V - Variable speed
T - Constant
Torque
(X-13)
P - PSC
A - 1st Design
040 - 42,000 [12.31 kW]
060 - 56,000 [16.41 kW]
070 - 70,000 [20.51 kW]
085 - 84,000 [24.62 kW]
100 - 98,000 [28.72 kW]
115 - 112,000 [32.82 kW]
1 - Single-stage
2 - Two-stage
M - Modulating
3 - up to 3 ton
5 - 3 1/2 up to 5 ton
14 - 14"
17 - 17.5"
21 - 21"
24 - 24.5"
M - Multi X - Low Nox
S - Standard
A - 1st Design
Air
Model Number Identification
RA16 Series
7
R
80 2 V A
075
3 17 M S A
Brand Series Stages Motor Major Rev Input
BTU/HR
Air Flow Cabinet
Width
Configuration Nox Minor Rev
Rheem
80 - 80+ AFUE 1 - Single-stage
2 - Two-stage
V - Variable speed
T - Constant Torque (X-13)
P - PSC premium
S - PSC standard
A - 1st Design
050 - 50,000 [15 kW]
075 - 75,000 [22 kW]
100 - 100,000 [29 kW]
125 - 125,000 [37 kW]
150 - 150,000 [44 kW]
3 - up to 3 ton
4 - 2 1/2 to 4 ton
5 - 3 1/2 up to 5 ton
14 - 14"
17 - 17.5"
21 - 21"
24 - 24.5"
M - Multi
D - Down
Z - Down &
zero clearance
down flow
X - Low Nox
S - Standard
A - 1st Design
R
H 1 T 36
17
S T A N A A 000 *
Brand Product
Category
Stages of
Airflow
Motor Type Capacity
BTU/HR
Width Coil Size Metering
Device
Major
Series*
Controls Voltage Minor
Series**
Factory Heat
Cap
Option
Code
Rheem
H - Air
Handler
1 - Single-Stage
2 - Two-Stage
M - Modulating
V - Variable
Speed
T - Constant
Torque
P - PSC
24 - 24,000 [7.03 kW]
36 - 36,000 [10.55 kW]
48 - 48,000 [14.07 kW]
60 - 60,000 [17.58 kW]
14 - 14"
17 - 17.5"
21 - 21"
24 - 24.5"
S - Standard
Eff.
M -Mid Eff.
H - High Eff.
T - TEV
E - EEV
P - Piston
A - 1st Design C -Communicating
N -Non-comm
A - 1ph, 115/60
J - 1ph, 208-240/60
D - 3ph, 480/60
A - 1st Design 00 - no
factory heat
with option
code
*TBD
90%+ AFUE Gas Furnaces (For Reference)
80% AFUE Gas Furnaces (For Reference)
Air Handlers (For Reference)
[ ] Designates Metric Conversions

Related product manuals