Air
General Data/Electrical Data
RA16 Series
8
Physical Data
PHYSICAL DATA
Model No. RA1618A RA1624A RA1630A RA1636B RA1642A RA1648A RA1660A
Nominal Tonnage 1.5 2.0 2.5 3.0 3.5 4.0 5.0
Valve Connections
Liquid Line O.D. – in. 3/8 3/8 3/8 3/8 3/8 3/8 3/8
Suction Line O.D. – in. 3/4 3/4 3/4 3/4 7/8 7/8 7/8
Refrigerant (R410A) furnished oz.¹ 82 87 113 108 150 174 201
Compressor Type Scroll
Outdoor Coil
Net face area – Outer Coil 12.1 14.8 16.2 17.29 24.2 28.3 32.3
Net face area – Inner Coil
Tube diameter – in. 3/8 3/8 3/8 3/8 3/8 3/8 3/8
Number of rows 1 1 1 1 1 1 1
Fins per inch 22 22 22 22 22 22 22
Outdoor Fan
Diameter – in. 20 24 26 24 26 26 26
Number of blades 3 2 3 3 3 3 3
Motor hp 1/8 1/6 1/5 1/6 1/3 1/3 1/3
CFM 2405 2850 3915 3300 4450 4660 4775
RPM 1095 851 710 825 829 828 795
watts 155 147 102 167 193 198 239
Shipping weight – lbs. 147 149 159 199 212 232 247
Operating weight – lbs. 140 142 152 192 205 225 240
Electrical Data
Line Voltage Data (Volts-Phase-Hz) 208/230-1-60 208/230-1-60 208/230-1-60 208/230-1-60 208/230-1-60 208/230-1-60 208/230-1-60
Maximum overcurrent protection (amps)² 20 20 30 35 40 40 50
Minimum circuit ampacity³ 12 14 18 21 25 25 34
Compressor
Rated load amps 9 10.3 12.8 15.4 16.7 17 23.7
Locked rotor amps 47.5 61.6 67.3 83.9 109 123.9 152.5
Condenser Fan Motor
Full load amps 0.7 0.6 1.4 0.8 3.5 5.3 3.5
Locked rotor amps 1.3 1.5 2.3 1.5 2.3
Line Voltage Data (Volts-Phase-Hz) 208/230-3-60 208/230-3-60 208/230-3-60 208/230-3-60
Maximum overcurrent protection (amps)²
20 25 30 35
Minimum circuit ampacity³
14 18 21 24
Compressor
Rated load amps 10.4 11.2 13.6 15.9
Locked rotor amps 73 88 83.1 110
Condenser Fan Motor
Full load amps 0.8 3.5 3.5 3.5
Locked rotor amps 1.5 2.3
¹Refrigerant charge sufficient for 15 ft. length of refrigerant lines. For longer line set requirements see the installation instructions for information about set length and additional
refrigerant charge required.
²HACR type circuit breaker of fuse.
³Refer to National Electrical Code manual to determine wire, fuse and disconnect size requirements.