Rheem Raypak D-2 Power Vent - Outdoor Vertical Venting Clearances

Rheem Raypak D-2 Power Vent
24 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
13
6" (15.2 CM)
MINIMUM **
6" (15.2 CM)
MINIMUM **
6" (15.2 cm)
MINIMUM **
12" (30.5 cm)
MINIMUM ***
16" (40.6 cm)
MINIMUM **
19" (48.3 cm)
MINIMUM **
6" (15.2 CM)
MINIMUM ***
* 7' MIN. (1.2 m) ABOVE PUBLIC WALKWAYS
* 3' MIN. (.91 m) ABOVE AIR INTAKES WITHIN 10' (3.0 m) RADIUS
* 43-3/4" MIN. (1.11 m) FROM PAD (LOW NOX HEATERS)
* 50" MIN. (1.27 m) FROM PAD (ATMOSPHERIC HEATERS)
* 7' MIN. (1.2 m) ABOVE PUBLIC WALKWAYS
* 3' MIN. (.91 m) ABOVE AIR INTAKES WITHIN 10' (3.0 m) RADIUS
* 43-3/4" MIN. (1.11 m) FROM PAD (LOW NOX HEATERS)
* 50" MIN. (1.27 m) FROM PAD (ATMOSPHERIC HEATERS)
17" (43.2 cm)
MINIMUM **
21" (53.3 cm)
MINIMUM **
6" (15.2 cm)
MINIMUM ** ***
12" (30.5 cm)
MINIMUM ** ***
6" (15.2 cm)
MINIMUM
6" (15.2 cm)
MINIMUM
* 7' MIN. (1.2 m) ABOVE PUBLIC WALKWAYS
* 3' MIN. (.91 m) ABOVE AIR INTAKES WITHIN 10' (3.0 m) RADIUS
* 43-3/4" MIN. (1.11 m) FROM PAD (LOW NOX HEATERS)
* 50" MIN. (1.27 m) FROM PAD (ATMOSPHERIC HEATERS)
* 7' MIN. (1.2 m) ABOVE PUBLIC WALKWAYS
* 3' MIN. (.91 m) ABOVE AIR INTAKES WITHIN 10' (3.0 m) RADIUS
* 43-3/4" MIN. (1.11 m) FROM PAD (LOW NOX HEATERS)
* 50" MIN. (1.27 m) FROM PAD (ATMOSPHERIC HEATERS)
* USE VERTICAL VENT PIPE TO MEET MINIMUM HEIGHT REQUIREMENTS
** MUST BE 4' (1.2 m) AWAY FROM ANY WINDOW, DOOR, OR GRAVITY AIR INLET
*** RECOMMENDED SERVICE CLEARANCES IS 24" (61 cm) FROM THE FRONT OF THE HEATER TO A WALL;
18" (45.7 cm) FROM THE WATER SIDE TO A WALL
6" (15.2 CM)
MINIMUM **
6" (15.2 cm)
MINIMUM **
Figure 25. Outdoor Clearances, Vertical Venting
APPROVED
UNCONTROLLED DOCUMENT IF PRINTED