11. Push in all four bracket tabs, so the Power Vent locks
into position. See Figure 13.
TAB TAB
Figure 13. Tab Location
12. Using a 5/16" nut driver, remove the transformer
cover located on the right side of the heater. See
Figure 14.
ACCESS SCREW
Figure 14. Transformer Cover Access
13. Install the right side outdoor conduit through the top
7/8" hole located on the right side of the heater. See.
Figure 15.
NOTE: You must rst remove the 7/8" plug on the heater
to install the hard conduit.
POWER
SUPPLY
POWER
VENT
Figure 15. Conduit Routing
14. Wire the heater power lines along with the D-2 Power
Vent power lines to the supply power per Figure 16
for 010744 or 010745, and per Figure 17 for 009832
or 009833. If the D-2 does not match the power
supplied, re-wire the blower for the correct voltage.
TO CONVERT FOR
240V OPERATION
FACTORY WIRED
120 VOLTS
D-2 POWER VENT
010744 & 010745
N
L1
120VAC
N.O
N.O C
Figure 16. 120VAC
APPROVED
UNCONTROLLED DOCUMENT IF PRINTED