Rheem Classic Plus
®
Series
Side Discharge Heat Pump
FORM NO. P11-821 REV. 1
RP17**H Series
Efficiency: 19 SEER/12 EER/10.7 HSPF
Nominal Sizes 2, 2.5, 3 & 4 Ton
[7.03, 8.8, 10.6 & 14.06 kW]
Cooling Capacities 24 to 45.6 kBTU
[7.03 to 13.36 kW]
Variable speed inverter-driven compressor for maximum
comfort and energy savings. Provides heating down to -5ºF
Outdoor sound levels as low as 53 dBA - quiet operation for
areas with noise constraints
Space saving single fan outdoor unit
High efficiency DC motor
Communicating heat pump with multi-position air handler
Compact size - ideal for areas with tight space constraints
Air
Heat Pumps
RP17**H Series
18.5

Other manuals for Rheem RHMV2421MNACJA

Question and Answer IconNeed help?

Do you have a question about the Rheem RHMV2421MNACJA and is the answer not in the manual?

Rheem RHMV2421MNACJA Specifications

General IconGeneral
BrandRheem
ModelRHMV2421MNACJA
CategoryAir Conditioner
LanguageEnglish

Summary

Rheem Classic Plus Series Side Discharge Heat Pump

Product Identification and SKUs

Details model number structure and available product codes for the series.

Physical Data Overview

Provides key physical specifications like dimensions, weight, airflow, and sound.

Electrical Characteristics

Outlines electrical requirements, wiring specifications, and circuit protection.

Included Accessories

Lists the accessories provided with the heat pump units.

Noise Level Curves (RP1724 HJVXA;RP1730 HJVXA)

Presents sound pressure level data for RP1724HJVXA and RP1730HJVXA models.

Noise Level Curves (RP1736 HJVXA;RP1748 HJVXA)

Shows sound pressure level data for RP1736HJVXA and RP1748HJVXA models.

Noise Level Measurement Setup

Explains the methodology and check points for measuring sound pressure levels.

Unit Dimensions (RP1724 HJVXA;RP1730 HJVXA)

Provides detailed dimensional drawings for specific models.

Unit Dimensions (RP1736 HJVXA;RP1748 HJVXA)

Displays dimensional drawings for other specific models in the series.

Detailed Unit Dimensions (RP1736 HJVXA;RP1748 HJVXA)

Continues detailed dimensional drawings for larger models.

Installation Space Requirements (RP1724 HJVXA;RP1730 HJVXA)

Specifies clearances for single outdoor unit installation.

Multiple Unit Installation Space (RP1724 HJVXA;RP1730 HJVXA)

Details clearances for multiple outdoor units side-by-side.

Multi-Row Installation Space & Notes (RP1724 HJVXA;RP1730 HJVXA)

Covers multi-row setups and provides installation notes and cautions.

Installation Space Cautions (RP1736 HJVXA;RP1748 HJVXA)

Highlights important cautions related to installation space for larger models.

Single Unit Installation Space (RP1736 HJVXA;RP1748 HJVXA)

Specifies clearances for single unit installation for larger models.

Multiple Unit Installation Space & Notes (RP1736 HJVXA;RP1748 HJVXA)

Details clearances for multiple units and provides installation notes.

Multi-Row Installation Space & Notes (RP1736 HJVXA;RP1748 HJVXA)

Covers multi-row setups and installation notes for larger models.

Wiring Diagram (RP1724 HJVXA;RP1730 HJVXA)

Illustrates the electrical wiring connections for specific models.

Wiring Diagram (RP1736 HJVXA;RP1748 HJVXA)

Shows the electrical wiring connections for other specific models.

Refrigerant Circuit Diagram (RP1724 HJVXA;RP1730 HJVXA)

Depicts the refrigerant flow paths for specific models.

Refrigerant Circuit Diagram (RP1736 HJVXA;RP1748 HJVXA)

Illustrates the refrigerant flow paths for other specific models.

Refrigerant Charge Calculation

Provides guidance on calculating refrigerant amounts based on pipe length.

Airflow Rates

Lists the airflow capacities for cooling and heating modes.

Capacity Compensation (Cooling)

Shows how cooling capacity is affected by pipe length and height difference.

Capacity Compensation (Heating)

Details how heating capacity is affected by pipe length and height difference.

Safety Devices and Protections

Describes the safety mechanisms and protection features of the unit.

Function Settings and Control Board

Explains how to set functions using the outdoor unit control board.

LED Display and DIP Switch Settings

Details the function of the LED display and various DIP switch settings.

Display Description and Low Noise Function

Describes display lamps, switch functions, and the low noise option.

Test Run Procedure

Guides users through the test run operation and initial checks.

Error Code Display and Interpretation

Explains how to read and interpret error codes displayed by the unit.

Comprehensive Error Code List

Provides a detailed list of all possible error codes and their meanings.

Pump Down Operation Procedure

Details the steps for safely performing a pump down operation.

Limited Warranty Information

Outlines the general terms and duration of the product warranty.