¢ Wall mounted type
Heating capacity in kBtu/h
TC: Total Capacity (kBtu/h).
The data is based on the following conditions:
Pipe length: 24.6 ft (7.5 m), Height difference: 0 ft (0 m) [Outdoor unit - Indoor unit]
MODEL: RIWH07AVFJ
Outdoor temperature
Indoor temperature (°FDB)
60.0 65.0 70.0 75.0 78.0
(°FDB) (°FWB) TC TC TC TC TC
5.0 3.0 5.15 5.03 4.91 4.78 4.66
14.0 12.0 5.81 5.67 5.53 5.39 5.26
23.0 19.0 6.47 6.31 6.16 6.00 5.85
32.0 28.0 7.53 7.35 7.17 7.00 6.82
41.0 37.0 8.60 8.40 8.19 7.99 7.78
47.0 43.0 8.82 8.61 8.40 8.19 7.98
50.0 47.0 8.82 8.61 8.40 8.19 7.98
59.0 50.0 8.82 8.61 8.40 8.19 7.98
68.0 59.0 8.42 8.22 8.02 7.82 7.62
75.0 65.0 8.02 7.83 7.64 7.45 7.26
MODEL: RIWH09AVFJ
Outdoor temperature
Indoor temperature (°FDB)
60.0 65.0 70.0 75.0 78.0
(°FDB) (°FWB) TC TC TC TC TC
5.0 3.0 6.62 6.47 6.31 6.15 5.99
14.0 12.0 7.47 7.29 7.11 6.94 6.76
23.0 19.0 8.31 8.12 7.92 7.72 7.52
32.0 28.0 9.69 9.46 9.22 8.99 8.76
41.0 37.0 11.06 10.80 10.53 10.27 10.01
47.0 43.0 11.34 11.07 10.80 10.53 10.26
50.0 47.0 11.34 11.07 10.80 10.53 10.26
59.0 50.0 11.34 11.07 10.80 10.53 10.26
68.0 59.0 10.82 10.56 10.31 10.05 9.79
75.0 65.0 10.32 10.07 9.82 9.58 9.33
MODEL: RIWH12AVFJ
Outdoor temperature
Indoor temperature (°FDB)
60.0 65.0 70.0 75.0 78.0
(°FDB) (°FWB) TC TC TC TC TC
5.0 3.0 8.83 8.62 8.41 8.20 7.99
14.0 12.0 9.96 9.72 9.48 9.25 9.01
23.0 19.0 11.08 10.82 10.56 10.29 10.03
32.0 28.0 12.91 12.61 12.30 11.99 11.68
41.0 37.0 14.74 14.39 14.04 13.69 13.34
47.0 43.0 15.12 14.76 14.40 14.04 13.68
50.0 47.0 15.12 14.76 14.40 14.04 13.68
59.0 50.0 15.12 14.76 14.40 14.04 13.68
68.0 59.0 14.43 14.09 13.74 13.40 13.06
75.0 65.0 13.75 13.43 13.10 12.77 12.44
- 111 -
OUTDOOR UNIT
ROMH45AFXZJ

Table of Contents