INSTALLATION
25
The water heater must not be installed in an area with a corrosive atmosphere
where chemicals are stored or where aerosol propellants are released.
Remember the air may be safe to breathe, but when it goes through a flame,
chemical changes take place which may attack the water heater.
The water heater must be located to ensure that the location of the flue terminal
complies with the requirements of AS 5601 or AS/NZS 5601.1, as applicable
under local regulations. As a guide the following requirements are extracted
from the Gas Installations Standard. The distances are measured along the
wall behind the water heater.
At least 500 mm between the
flue terminal and the edge of any
opening into the building, such
as an openable door or window,
measured horizontally* and
vertically.
At least 500 mm between the
flue terminal and a return wall or
external corner, measured
horizontally*.
At least 500 mm from of any
combustibles.
Note: * If these horizontal distances cannot be achieved, AS/NZS 5601.1
states an equivalent horizontal distance measured diagonally from the nearest
discharge point of the flue terminal to the opening may be deemed to comply.
Check with the local regulator.
SAFE TRAY
Where damage to property can occur in the event of the water heater leaking,
the water heater must be installed in a safe tray. Construction, installation and
draining of a safe tray must comply with AS/NZS 3500.4 and all local codes
and regulatory authority requirements.
CLEARANCE REQUIREMENTS
330 SS Gas Domestic Outdoor Water Heater