INSTALLATION
30
TYPICAL INSTALLATION OUTDOOR LOCATION
GAS SUPPLY PIPE
Isolating valve and
union must be used.
COLD WATER
CONNECTION
Cold water connection
must comply with local
regulations.
ACCESS COVER
Lighting instructions
are on the back of this
door. The rating label
can be found on the
internal panel when the
door is removed. Door
must be replaced after
lighting and remain in
place when the water
heater is operating.
TYPICAL INSTALLATION
STAINLESS STEEL GAS WATER HEATER
PIEZO IGNITER inside.
BASE
Level, stable impervious
base designed to avoid
ponding.
FLUE TERMINAL
Minimum distance to
windows, doors and
walls must be in
accordance with
regulatory authority
requirements.
WALL BRACKET
HOT WATER OUTLET
Use a union connection
and insulate hot water
pipe.
INSULATED HOT
WATER PIPE
TEMPERATURE
PRESSURE RELIEF
VALVE DRAIN LINE
Drain line must
terminate away from the
base of the water heater.
Discharge point must
comply with local
installation requirements.
TEMPERATURE
PRESSURE RELIEF
VALVE
COLD WATER INLET