BC-35
Currency Counter
User Manual

Questions and Answers

  • P
    Pamela PriceSep 9, 2025
    What does counting error code 251 mean on my Ribao BC-35?
    • B
      brandyhallSep 9, 2025
      If your Ribao Cash Counter displays counting error code 251, this indicates a left UV warning.
  • C
    Carolyn HowardAug 23, 2025
    What does counting error code 151 mean on a Ribao BC-35?
    • S
      Stephanie BaileyAug 23, 2025
      Counting error code 151 on the Ribao Cash Counter indicates that double notes were detected.
  • C
    Cynthia MartinAug 25, 2025
    What does it mean if my Ribao BC-35 shows counting error code 452 or 453?
    • E
      Eric KaiserAug 25, 2025
      If your Ribao Cash Counter displays counting error codes 452 or 453, this indicates chained notes were detected.
  • J
    jadamsAug 26, 2025
    What does counting error code 451 mean on my Ribao Cash Counter?
    • K
      keithsnowAug 27, 2025
      If your Ribao Cash Counter displays counting error code 451, this indicates that half notes were detected.
  • O
    osbornebrettAug 28, 2025
    What does counting error code 551 mean on my Ribao BC-35 Cash Counter?
    • R
      Robin JimenezAug 28, 2025
      If your Ribao Cash Counter displays counting error code 551, this indicates a size error was detected.
  • M
    Megan BennettAug 29, 2025
    What does counting error code 454 mean on my Ribao Cash Counter?
    • C
      Christopher ThomasAug 29, 2025
      If your Ribao Cash Counter displays counting error code 454, this indicates inclined notes were detected.
  • C
    cindy15Sep 18, 2025
    What to do if Ribao BC-35 displays self-test error code 191?
    • Z
      zbarberSep 18, 2025
      If your Ribao Cash Counter displays self-test error with code 191, it means the left side MG quantity is greater than 1. Check if notes stay in the passage.
  • K
    Kimberly CoxSep 19, 2025
    What to do if Ribao Cash Counter displays self-test error code 192?
    • R
      Robert AdamsSep 19, 2025
      If your Ribao Cash Counter displays self-test error with code 192, it means the right side MG quantity is greater than 1. Check if notes stay in the passage.
  • A
    Aaron Mason VSep 7, 2025
    What does counting error code 252 mean on my Ribao Cash Counter?
    • S
      Samuel BrownSep 7, 2025
      If your Ribao Cash Counter displays counting error code 252, this indicates a right UV warning.
  • C
    cjamesSep 4, 2025
    What to do if Ribao Cash Counter displays self-test error code 193?
    • C
      Christopher JacksonSep 5, 2025
      If your Ribao Cash Counter displays self-test error with code 193, it means the hopper sensor is blocked. Check if the hopper sensor is covered by dust or blocked.

Summary

Installation Guidelines for Currency Counter

General Installation Procedures

General guidelines for installing the currency counter, including distributor contact.

Optimal Installation Location Requirements

Recommendations for machine placement, considering operational space and maintenance.

Technical Specifications

Display and Operation Interface Overview

Control Panel Key Functions

Detailed explanation of each button's function on the control panel for operation.

Software Interface Symbol Explanation

Explanation of the symbols and indicators displayed on the machine's interface.

Operating the BC-35 Currency Counter

Initial Operation Steps

Basic steps for powering on the machine and entering the initial loading interface.

Configuring Batch Counting

Instructions on how to activate and configure the batch counting function.

Setting Counterfeit Detection Modes

Guide to activating and adjusting UV and MG counterfeit detection modes.

Adjusting Counting Speed Levels

How to adjust the counting speed levels of the machine (High, Medium, Low).

Using Accumulative Counting (ADD)

How to enable and use the accumulative counting (ADD) function for total counts.

Troubleshooting Common Issues

Firmware Upgrade Procedure

Daily Maintenance and Cleaning

Ribao BC-35 Specifications

General IconGeneral
BatchingYes
Add FunctionYes
Power SupplyAC 110V-220V, 50/60Hz
Counting Speed1000 pcs/min
Detection MethodsUV, MG