4- 5+
Available
6- 7+ 24Vdc power supply for accessories
8- 9+ ACG9631 Emergency batteries back-up connection
10- COM Common inputs (negative).
11 - FCA
Opening limit switch (connected in factory)
12 - FOTO RAL Input Exclusion for Safety 14
13 - STOP
N.C. safety, the opening of the contact (16-18) stops the movement of the door and inhibits any command. The
resetting of the contact and a subsequent “open” command makes the door open completely in slow motion;
then it will wait for an OPEN command.
The automation will resume the automatic operation with the previous parameters.
14 - FOTO
N.C. Input terminal for a pair of safety photocells; the interruption of the open door range keeps the automatic
closure time paused until such range is resumed, whereas in the closure phase, it reverses the movement.
15 - R. EXT Outward opening sensor; it sends an “open” command. In “closure” phase, it reverses the movement.
16 - R. INT Inward opening sensor; it sends an “open” command. In “closure” phase, it reverses the movement.
17 - OPEN
neg.
N.O. input, if closed with input COM (22-16), it “opens” the automation keeping it in position until the contact
itself is reopened.
Set parameter “I” to 0 on the LCD PROGRAMMER (optional) in order to manage the open-close orders
alternately; Automatic closure is not active.
Set parameter “I” from 1 to 9 according to the desired automatic closure time ( I1=1 s , I2=2 s ,
etc...).
18 - INT. I
19 - INT. O
Interlock feature (anti-tailgating); connecting terminal 18 (INT.I) of a control panel to terminal 19 (INT.O) of
another one and vice versa. The automation that first get an “open” command will lock the second automation
(closed door) until the first one is completely closed.
30 - OPEN-HCP
N.O. soft touch command for mobility-impaired.
This command opens the door increasing to 30s the pause time before automatic closure.
31- COM Common inputs (negative).
COM10
G