Mode No. Function Settings
Class 1 Class 2
1104 *
Fusing
Temperature
Control
Selects the fusing temperature control
mode.
On/Off
Phase
1105 *
Fusing
Temperature
Adjustment
Adjusts the fusing temperature. 170 ~ 200
1°C/step
185°C
1106
Fusing
Temperature
Display
Displays the fusing temperature.
2001 *
1 *
Grid Voltage
Adjustment
(For copying)
Adjusts the voltage applied to the grid
plate during copying.
600 ~ 1000
1 V/step
890 V
Do not adjust.
2 *
Grid Voltage
Adjustment
(For ID sensor
pattern)
Adjusts the voltage applied to the grid
plate when making the ID sensor pattern.
600 ~ 1000
1 V/step
650 V
Do not adjust.
5 *
Charge
Corona
Current
Adjustment
Adjusts the current applied to the charge
corona wire.
900 ~ 1300
1
µ
A/step
1100
µµ
A
Do not adjust.
2101 *
1 *
Leading Edge
Erase Margin
(Printing)
Adjusts the leading edge erase margin. 0.0 ~ 9.0
0.1 mm/step
3.0 mm
The specification is 3
±
2 mm. See
"Replacement and Adjustment - Copy
Image Adjustments" for details on
SP2101.
2 *
Trailing Edge
Erase Margin
(Printing)
Adjusts the trailing edge erase margin. 0.0 ~ 9.0
0.1 mm/step
2.0 mm
The specification is 2
±
2 mm.
3 *
Left Side
Edge Erase
Margin
(Printing)
Adjusts the left side erase margin. 0.0 ~ 9.0
0.1 mm/step
2.0 mm
The specification is 2
±
1.5 mm.
4 *
Right Side
Edge Erase
Margin
(Printing)
Adjusts the right side erase margin. 0.0 ~ 9.0
0.1 mm/step
1.0 mm
The specification is 2
+
2.5
1.5
mm.
2103 *
LD Power
Adjustment
Adjusts the LD power. -127 ~ +127
2.1
µ
W/step
+0
Do not change the value.
SERVICE PROGRAM MODE TABLES 25 April 1997