Mode No. Function Settings
Class 1 Class 2
2950 *
Side-to-Side
Registration
(Base)
Changes the printing start position. - 12.7 ~ + 12.7
0.1 mm/step
+ 0.0 mm
Factory use only
3001
ID Sensor
Initial Setting
Performs the ID sensor initial setting. The
ID sensor output for the bare area of the
drum (V
SG
) is adjusted to 4.0
±
0.2V.
This SP mode should be performed after
replacing or cleaning the ID sensor or
replacing the drum.
3103 *
ID Sensor
Output
Display
Displays the current V
SG
and V
SP
output. V
SP
=
Q
.
QQ
V
V
SG
=
Q
.
QQ
V
If the ID sensor does not detect the ID
pattern, "V
SP
=5.0v/V
SG
=5.0v" is displayed.
If the ID sensor does not detect the bare
area of the drum, "V
SP
=0.0v/V
SG
=0.0v" is
displayed.
4008 *
Sub Scan
Magnification
(Scanning)
Adjusts the magnification in the sub scan
direction for scanning.
If this value is changed, the scanner
motor speed is changed.
- 9.0 ~ + 9.0
0.1 %/step
+ 0.0 %
Use the
•/∗
key to toggle between + and -.
See "Replacement and Adjustment -
Copy Image Adjustments"in the AD3
service manual for details.
4010 *
Leading Edge
Registration
(Scanning)
Adjusts the leading edge registration for
scanning.
- 9.0 ~ + 9.0
0.1 mm/step
+ 0.0 mm
(-): the image moves in the direction of
the leading edge
Use the
•/∗
key to toggle between + and -.
See "Replacement and Adjustment -
Copy Image Adjustments"in the AD3
service manual for details.
4011 *
Side-to Side
Registration
(Scanning)
Adjusts the side-to-side registration for
scanning.
- 9.0 ~ + 9.0
0.1 mm/step
+ 0.0 mm
(-): the image disappears at the left side.
(+): The image appears.
Use the
•/∗
key to toggle between + and -.
See "Replacement and Adjustment -
Copy Image Adjustments"in the AD3
service manual for details.
SERVICE PROGRAM MODE TABLES 25 April 1997