Efficiency Class | A |
---|---|
Max working pressure | 3 bar |
Mounting | Wall-mounted |
Fuel Type | Gas |
Gas connection | 3/4 inch |
Electrical supply | 230V |
Check product integrity upon receipt and ensure installation complies with standards.
Use the boiler only for its intended purpose; manufacturer not liable for damages from improper use.
Disconnect power, shut water supply, and notify assistance in case of leaks.
Steps for non-use: switch off main power, fuel/water taps, and empty system if freezing risk.
All maintenance must be by qualified professionals; use only original accessories.
Dispose of packaging responsibly and the product as differentiated waste at end-of-life.
Disconnect power before cleaning; use appropriate cleaning agents.
In case of fuel smell, ventilate, close fuel device, and call for assistance.
Avoid touching the appliance barefoot or with wet body parts; disconnect power before any operation.
Do not modify safety devices without authorization; do not intervene on sealed elements.
Do not plug condensate drain, pull cables, reduce ventilation, expose to elements, or leave flammable containers.
Device is not for unsupervised use by persons with reduced capabilities; supervise children.
Dispose of packaging properly; do not place objects on the boiler.
Use the appliance only for its specified purposes.
Describes the gas boiler type, fuel compatibility, and electronic control features.
Identifies and explains the main controls and indicator lights (A, B, C, D).
Outlines checks and operations for the first start-up, typically by an assistance centre.
Steps for restarting the boiler after a prolonged period of inactivity.
Verifies gas/water taps are open and checks green light status after setting main dial to "ON".
Instructions for setting the domestic hot water temperature using control B.
How to increase or decrease domestic hot water temperature using control B.
Describes boiler startup sequence upon opening a hot water tap and normal operation indicators.
Explains "LOCKOUT" conditions, red light signal, and troubleshooting steps for burner block.
How the boiler behaves during and after a power cut, including automatic restart.
Procedure for temporary switch-off for weekends or short trips.
Steps to turn off the boiler for long periods, including main switch and taps.
Advice to empty the system if there is a risk of freezing during extended shutdown.
Boiler maintenance must be performed annually by a Technical Assistance Centre or qualified personnel.
Instructions for cleaning external panels using mild soap and water or a spirit mixture.
Do not use abrasive cleaners; always disconnect power before cleaning.
Checks and steps to take if the boiler fails to start up.
Actions to take if the burner fails to switch off when the hot water tap is turned off.
Table explaining the meaning of GREEN and RED LED signals and operating status.