Programmable Relay User Manual for ELC, EXM and PR Series 277 2020 v6.0 © Rievtech Co.,
Ltd. www.rievtech.com
Status: Status of a variable, you have to click on the
corresponding Setbutton.
Changing the state of a variable:
Variable I:
You cant change the status of variable I.
Variable Q:
When the input pin of output block Q is not connected,
you can change the status of variable Q.
If the input pin of output block Q is already connected
with other blocks, you cant change the status of variable
Q anymore.
Variable AI:
You cant change the value of variable AI.
Variable AQ:
When the input pin of analogue output block AQ is not
connected, you can change the value of the variable AQ.
If the input pin of analogue output block AQ is already
connected with other blocks, you cant change the value
of that variable anymore.
Variable F:
When the input pin of digital flag variable F is not
connected, you can change the status of variable F.
If the input pin of the digital flag block F is already
connected with other blocks, you can’t change the status
of that variable anymore.
Variable AF:
When the input pin of analogue flag block AF is not
connected, you can change the value of variable AF.
If the input pin of analogue flag block AF is already
connected with other blocks, you cant change the value
of that variable anymore.
Variable HEG:
Cannot be set, can only be read.
Variable M:
You cant change the status of a variable M; it can only be
read.