EasyManua.ls Logo

Rievtech ELC Series - Page 42

Rievtech ELC Series
355 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
EN
Programmable Relay User Manual for ELC, EXM and PR Series 42 2020 v6.0 © Rievtech Co.,
Ltd. www.rievtech.com
How to Change GPRS Parameters and Setting by SMS
FORMAT: ##**PGPRS:<parameter>”<value>”,<parameter>”<value>”,…,<parameter>”<value>”;
The following parameters may be changed by SMS, which can be done with one SMS by separating parameters with a
comma (,).
NOTICE:
The PGRPS command can have a maximum of 100 characters.
##** (Start of Message Characters)
PGPRS: (Command)
TIMEOUT”60”, (Unit: secs Minimum 30)
IPORDOMAIN”0”, (Network Mode Change 0 = Use IP Address, 1 = Use Domain Name)
POWCONNECT”0”, (Connect to Ethernet on Power On 0 = No, 1 = Yes)
APN”CMNET”, (Change APN)
TADR”221.226.189.74”; (Change Target IP Address)
TPORT”5005”, (Change Target Port Number)
SNUMB”12345678”, (Change Device Name Max. 8-characters)
DOMAIN”www.rievtech.co.uk”, (Change Domain Name)
; (End of Message Character)
Example
Change Timeout to 35 secs, APN to RIEVTECH, Port number to 8008
##**PGPRS:TIMEOUT”35”,APN”RIEVTECH”,TPORT”800”;