RIGOL
© Copyright RIGOL Technologies, Inc. 2007. 5-3
User Manual for DM3000 Series
To change the electric power fuse
The electric power fuse located in the rear of the Multimeter, the fuse is a kind of
delay, no-burst, 250V/300mAT,5×20mm one.
Operation steps
1. Cut off the power. Use the tool to press down the block lingua(as the dashed
line point out), and then pull out the seat of the fuse.
2. Choose the correct voltage shelves location in the voltage selected switches.
3. Enclose the seat of the fuse to the slot after placed the fuse.
Figure 51
The sketch map of changing the electric power fuse