Condions LCD Status For checking the following: Acon:
0.0V - 3.9V Normal Display
4.0V - 4.5V Sensor volt (Low) Check sensor connecon
4.6V - 6.0V Sensor volt (OK)
6.1V - 7.5V Sensor volt (On high side) Refer Service Manual
7.6V - 12.2V Sensor volt (High)
12V Baer volt (Low)
Sensor: Refer Service Manual
12V Baery: <10.6V: Replace >10.7V: Recharge and test
12.3V - 12.5V 12V Baery volt (Marginal) Recharge baery
12.6V - 13.5V 12V Baery volt (OK)
13.6V - 13.9V 12V Alternator charging volt (Low) Check alternator, loose belt etc.
14.0V - 14.9V 12V Alternator charging volt (Normal)
15.0V - 15.5V 12V Alternator charging volt (High)
15.6V - 17.5V 12V Smart Alternator charging volt (Normal)
24V Baery volt (Low)
Normal alternator: Check regulator. Smart alternator: Ignore
24V Baery: Replace
17.6V - 24.6V 12V Smart Alternator charging volt (High)
24V Baery volt (Low)
Check alternator/seng
24V Baery: <21.2V: Replace >21.3V: Recharge and test
24.7V - 25.0V 24V Baery volt (Marginal) Recharge baery
25.1V - 27.0V 24V Baery volt (OK)
27.1V - 27.9V 24V Alternator charging volt (Low) Check alternator, loose belt etc.
28.0V - 29.9V 24V Alternator charging volt (Normal)
30.0V - 31.0V 24V Alternator charging volt (High) Check regulator
31.1V - 35.0V 24V Smart Alternator charging volt (Normal) Ignore
35.1V - 37.5V 24V Smart Alternator charging volt (High) Check alternator/seng
>37.6V Normal Display
7
5.3 Voltage Measurement
1. Turn Selector Dial to Voltage Mode (V posion)
2. Select Voltage Mode then press
buon to connue
3. Connect probes to circuit to be tested red=posive(+), black=negave(-)
4. Display will then show correct voltage
While measuring voltage, the Status Indicator will also illuminate to give a quick indicaon of correct voltage for 5V, 12V or 24V power sources
For example when measuring voltages from a vehicle ECU
Good
Voltage OK
Marginal
Check Voltage
Low/High
Voltage outside limits
GB