This appliance shall be installed in accordance with:
• Manufacturers Installation Instructions
• Current AS/NZS 3000
• Local Regulations and Municipal Building Codes including local OH&S requirements
This appliance must be installed, maintained and removed by an Authorised Person.
For continued safety of this appliance it must be installed and maintained in
accordance with the manufacturers instructions.
HINRA26M
HINRA35M
HINRA50M
HINRA70M
HINRA80
HSNRA26
HSNRA35
HSNRA50
HSNRA70
HSNRA80
HONRA26
Indoor System Outdoor
HONRA35
HONRA50
HONRA70
HONRA80
Rinnai System Models
HINRA20MReference Only Matching Multi System Only
Owners Manual
Split Type Wall Mounted Air Conditioner

Other manuals for Rinnai HINRA35M

Question and Answer IconNeed help?

Do you have a question about the Rinnai HINRA35M and is the answer not in the manual?

Overview

This document is the Owner's Manual for a Rinnai Split Type Wall Mounted Air Conditioner. It provides essential information for the safe operation, maintenance, and optimal performance of the appliance.

Function Description

The Rinnai Split Type Wall Mounted Air Conditioner is designed to provide consumer comfort by regulating room temperature. It operates in various modes including Cool, Heat, and Dry, and features a fan-only mode. The unit can be controlled via a remote control, which allows for adjustments to temperature, fan speed, and airflow direction. In cases where the remote control is unavailable, a manual ON/OFF (Auto) button on the indoor unit provides basic operational control. The system includes features such as Auto-Restart after power interruption, Anti-mildew operation, Mute Operation for a quiet environment, Wi-Fi Control (where fitted) for mobile phone operation, Louvre Angle Memory, and Refrigerant Leakage Detection.

Important Technical Specifications

The manual lists several Rinnai System Models, including HSNRA26, HSNRA35, HSNRA50, HSNRA70, and HSNRA80, each with corresponding Indoor (HINRAxxM) and Outdoor (HONRAxx) unit models. A "Reference Only" model, HINRA20M, is specified for matching multi-system use only. The appliance uses R410A refrigerant. Optimal performance is achieved within specific temperature ranges:

  • Cool Mode: Room Temperature 17°C ~ 32°C, Outdoor Temperature -15°C ~ 50°C
  • Heat Mode: Room Temperature 0°C ~ 30°C, Outdoor Temperature -15°C ~ 30°C
  • Dry Mode: Room Temperature 17°C ~ 32°C, Outdoor Temperature 0°C ~ 50°C Operating outside these ranges may activate safety protection features, affecting performance. The remote control uses AAA (1.5 V) batteries.

Usage Features

  • Remote Control Operation: The primary method of control, allowing for precise adjustments. The remote control should be pointed towards the signal receiver on the indoor unit.
  • Manual Operation: A button on the indoor unit allows for temporary operation in FORCED AUTO mode (automatic cooling, heating, and fan speed) or FORCED COOLING mode (lowest temperature, highest fan speed) when the remote control is not available.
  • Airflow Adjustment: Vertical airflow (louvre angle) can be adjusted using the SWING/DIRECT buttons on the remote control for fixed positions or continuous circulation. Horizontal airflow adjustment details are available in the Remote Control Manual.
  • Sleep Operation: This function, activated via the remote control, reduces energy consumption during sleep. In cooling mode, the temperature increases by 1°C after 1 hour, and another 1°C after a second hour, then maintains this setting for 7 hours before turning off. In heating mode, the temperature decreases similarly. Sleep mode is not available in FAN or DRY modes.
  • Automatic Restart: In case of a power outage, the unit will automatically restart with its previous settings once power is restored, after an approximate 5-minute restart cycle.
  • Display Window States: The indoor unit's display shows various indicators such as "ON" (Timer ON, Fresh, Swing, Turbo, Silence ON), "OF" (Timer OFF, Fresh, Swing, Turbo, Silence OFF), "CF" (anti-cold air), "dF" (defrosting), "SC" (self-cleaning), "FP" (freeze protection), and "E-C-O" (ECO function with set temperature). In Fan mode, room temperature is displayed; in other modes, the set temperature is shown.

Maintenance Features

  • Indoor Unit Cleaning: Wipe with a soft dry cloth; a warm damp cloth can be used for dirtier surfaces. Avoid water inside the unit, chemicals, harsh detergents, benzene, paint thinners, polishing powder, or solvents. Water hotter than 40°C should not be used on the front panel.
  • Air Filter Cleaning: Filters should be inspected and cleaned at least every two weeks. Dirty filters reduce efficiency and air quality.
    1. Grip the filter tab, lift, and pull out.
    2. If present, unclip the small air freshening filter from its holder.
    3. Clean filters with a vacuum cleaner or warm water with mild detergent.
    4. Rinse with fresh water and shake off excess.
    5. Dry in a cool, dry place, away from direct sunlight.
    6. Re-insert securely and close the front panel.
    • Do not operate the system without filters.
    • Avoid touching metal parts during filter removal.
    • Do not use chemicals or volatile substances on filters.
  • Filter Reminder (where fitted):
    • Cleaning Reminder: "CL" flashes after 240 hours of use. Reset by pressing the LED button on the remote control 4 times or the Manual Control button 3 times.
    • Replacement Reminder: "F" flashes after 2,880 hours of use. Reset in the same manner as the cleaning reminder.
  • Outdoor Unit Cleaning: Periodically inspect to ensure no vegetation obstructs the unit. Keep the cabinet clean and maintain recommended clearances. Ensure no water build-up. Any maintenance or cleaning of the outdoor unit must be performed by an authorised dealer or licensed service provider.
  • General Maintenance (Prolonged Non-Use):
    • Clean all filters.
    • Run Fan function until the unit is completely dry.
    • Turn off the unit and disconnect power.
    • Remove batteries from the remote control.
  • General Maintenance (Pre-Season Inspection):
    • Check for damaged wires.
    • Clean all filters.
    • Check for leaks.
    • Replace batteries.
    • Ensure all air inlets and outlets of both indoor and outdoor units are unobstructed.
  • Professional Servicing: The air conditioning system should be maintained annually by a qualified licensed technician. Failure to do so may void the warranty. Service maintenance is not covered under warranty and is a chargeable service.

Safety Warnings and Important Information

The manual emphasizes reading all instructions, complying with precautions, and noting that failure to do so can result in malfunction, property damage, injury, or death.

  • Installation: Must be performed by an Authorised Person in accordance with manufacturer's instructions, AS/NZS 3000, and local regulations. The appliance is heavy and requires two people or a mechanical lifting device for installation.
  • Electrical: Do not modify wiring. Damaged wiring must be replaced by an authorized person.
  • Placement: Do not install on unstable or non-level surfaces, or where it may fall. Avoid installing the outdoor unit where noise may cause nuisance or where it will be exposed to sea wind (salt spray).
  • Operation: Do not run for extended periods in high humidity with open doors/windows. Do not cover the appliance. Do not touch or operate with wet hands. Do not insert objects into air inlets/outlets. Avoid placing heating appliances near the unit without sufficient ventilation. Turn off main power before cleaning. Do not touch metal parts when removing air filters. Do not leave flammable materials near the appliance. If excessive noise, smell, or smoke occurs, turn off the appliance, isolate power, and contact service. Do not operate if submerged in water.
  • User Restrictions: Not intended for use by persons (including children) with reduced physical, sensory, or mental capabilities without supervision. Children should be supervised to prevent play with the appliance.
  • Condensate Water: Do not drink condensate water.
  • Airflow: Do not block air inlets or outlets. Do not expose people, animals, or plants directly to cold/hot discharge.
  • Remote Control Batteries: Do not mix battery types or new with used batteries. Stop use if battery fluid leaks.
  • Power Connections: Do not use extension cords, manually extend power cords, or connect other appliances to the same outlet.

Warranty Exclusions

The Rinnai product warranty excludes faults due to improper use, abuse, fair wear and tear, or failure to follow service and maintenance instructions. Regular maintenance and servicing are conditions of the warranty. Specific exclusions include damage from improper operation/maintenance, faulty installation, external factors (electrical issues, acts of God, weather), re-installation at a different location, consumable items (filters, batteries), third-party components, exposure to moisture/chemicals, accidents, use outside specified operating range, and fair wear and tear. Service maintenance is a chargeable service.

Rinnai HINRA35M Specifications

General IconGeneral
BrandRinnai
ModelHINRA35M
CategoryAir Conditioner
LanguageEnglish

Related product manuals