Condensing Water Heater Service Manual 43 100000354
KB Series Component Replacement Instructions
RU80i/e, RU98i/e
Heat Exchanger
1.Turn off gas supply.
2.Turn off 120 V power supply.
3.Turn off water supply and drain unit.
4.Remove four screws securing front panel. Remove front panel.
5.Disconnect solenoid valve harnesses (SV1, SV2, SV3), flame rod wire (yellow), electrode wire (black). (FIGURE 1)
6.Disconnect fan harness, thermal fuse harnesses (upper & lower FIGURES 2 & 3), igniter harness, & burner sensor
harness. Remove 1 screw from gas pipe to manifold connection and rotate gas pipe to the right to move it out of the
way. (Put screw back into connection so as not to lose it) (External Units will have a freeze protection thermistor)
(FIGURE 2)
7.Disconnect thermal fuse harness, heat exchanger thermistor connection, ceramic heaters, bi-metal connectors, &
remove controller bracket. (FIGURE 3)
Fan Harness
Burner Sensor Wire
Thermal Fuse Harness
Igniter Harness
FIGURE 1
Solenoid Harnesses
Flame Rod Wire Electrode Wire
FIGURE 3
Thermal Fuse Harness
Thermistor Connection
Ceramic Heaters
Bi-Metal
Connectors
Bracket
Screw
FIGURE 2

Other manuals for Rinnai REU-KA2530FFUD-US

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rinnai REU-KA2530FFUD-US and is the answer not in the manual?

Rinnai REU-KA2530FFUD-US Specifications

General IconGeneral
BrandRinnai
ModelREU-KA2530FFUD-US
CategoryWater Heater
LanguageEnglish

Related product manuals