12
The appliances comply with the Electrical Products (Safety) Regulation in Hong Kong.
Specifications
Model RS11TML RS11RML
Basic
Specifications
Appliance Type Fan Draught Room-sealed Type
Installation Type Wall-mount Type
Flue Type Top Flue Back Flue
Dimensions - W x H x D (mm) 370 x 675 x 135
Weight (kg) 14.5
Gas Type Hong Kong LPG
Gas Supply Pressure (kPa) 2.9
Gas Connection 1/2” BSP
Water Pipework
Connections
Cold Water 1/2” BSP
Hot Water 1/2” BSP
Power Supply & Signal
Connections
Power Supply A.C. 220V 50Hz
Signal Cable /
Exhaust Connections
(mm)
Flue Terminal Circular Type
Flue Diameter
Air Inlet Connection: Ø100 /
Exhaust outlet Connection:
Ø60
Air Inlet Connection: Ø110 /
Exhaust outlet Connection:
Ø75
Flue Length
Maximum 5m & 3 bend
(1 bend equivalent to 2m)
/
Ignition Type Automatic Spark Ignition
Rated Heat Input (kW)
Maximum 26.7
Minimum 6.5
Electrical Consumption (W) 50
Level of Water-proof
Body IPX4
Remote Control /
Operation
System
Amount of Hot Water Supply with 25°C
Temperature Rise (L/min)
12.0
Amount of Hot Water Supply Range (L/min) 2.4 to 12.0
Minimum Hot Water Flow (L/min) 2.4
Minimum Operation Water Pressure (kPa) 10
Range of Normal Operation Water Pressure (kPa) 70 to 700
Range of Hot Water Temperature (°C) 35, 37 to 48, 50 & 55
Safety
Devices
Flame Failure Safety Device Flame Rod
Remaining Flame Protection Device Bi-metal Switch (90°C)
Over Boiling Protection Device Thermistor (95°C)
Overheat Protection Device Thermal Fuse (150°C)
Over Pressure Protection Device Pressure Relief Valve (ON: 2100kPa)
Water Flow Sensing Device Water Flow Sensor
Combustion Fan Revolution Checking Device Speed Detection Sensor
Over Electrical Current Protection Device Fuse (3A)
Earth Leakage Protection Device Earth Leakage Circuit Breaker
Accessories
Remote Control (Wired)
※ Optional to purchase
/