What does Fault Code 16 mean on my Rinnai RS11TML?
- JJessica SanchezSep 8, 2025
Fault Code 16 indicates that the over boiling protection device has been activated. Please call service.
What does Fault Code 16 mean on my Rinnai RS11TML?
Fault Code 16 indicates that the over boiling protection device has been activated. Please call service.
What does Fault Code 32 mean on my Rinnai RS11TML Water Heater?
Fault Code 32 indicates that the outgoing water temperature sensor is faulty. Please call service.
What does Fault Code 34 mean on my Rinnai Water Heater?
Fault Code 34 indicates that the air temperature sensor is faulty. Please call service.
Flow Rate | Up to 11 GPM |
---|---|
Energy Factor | 0.82 |
Energy Efficiency | 82% |
Ignition Type | Electronic |
Water Connection | 3/4" NPT |
Type | Tankless |
Temperature Range | 98°F - 140°F |
Electrical Requirements | 120 VAC |
Warranty | 12 years heat exchanger, 5 years parts, 1 year labor |
Explains the meaning of danger, warning, and caution alerts and associated symbols.
Steps for gas leaks, abnormal operation, earthquakes, and fires.
Guidelines for safe installation location, flue gas discharge, and fire prevention.
Covers control unit safety, operation tips, cleaning advice, and child supervision.
Details the components of the front panel control.
Explains the temperature display and operation indicator light.
Describes the buttons for adjusting temperature and turning the appliance on/off.
Cautions for first use, ignition, water flow sounds, and long non-use.
Instructions on checking water temperature to prevent burns.
Steps for checking operation and setting initial hot water temperature.
How to start the appliance and adjust hot water temperature.
Guidelines for using hot water and how to stop appliance operation.
Details various safety devices and their roles.
Advice on adjusting temperature based on seasons and flow.
Instructions for cleaning the appliance and regular maintenance.
Lists fault codes, reasons, and recommended remedies.
Covers problems like no hot water, fluctuating flow, and temperature variations.
Addresses issues with indicators, fan operation, flame failure, flue mist, milky water, pressure relief, and temperature settings.