Conversion Manual for Condensing Tankless Water Heaters
for the conversion from Natural Gas (NG) to Liquid Propane Gas (LPG)
for the conversion from Liquid Propane Gas (LPG) to Natural Gas (NG)
WARNING
This conversion kit shall be installed by a qualied service agency
in accordance with the manufacturers instrucons and all
applicable codes and requirements of the authority having
jurisdicon. The informaon in these instrucons must be
followed to minimize the risk of re or explosion or to prevent
property damage, personal injury or death. The qualied service
agency is responsible for the proper installaon of this kit. The
installaon is not proper and complete unl the operaon of the
converted appliance is checked as specied in the manufacturers
instrucons supplied with the kit.
Residenal models are cered for installaon in mobile
CU199i ...................... (REU-N3237FFC-US)
CU160i ...................... (REU-N2530FFC-US)
CU199e ..................... (REU-N3237WC-US)
CU160e ..................... (REU-N2530WC-US)
COMMERCIAL
RU199i ...................... (REU-N3237FF-US)
RU180i ...................... (REU-N2934FF-US)
RU160i ...................... (REU-N2530FF-US)
RU130i ...................... (REU-N2024FF-US)
RUR199i .................... (REU-NP3237FF-US)
RUR160i .................... (REU-NP2530FF-US)
RU199e ..................... (REU-N3237W-US)
RU180e ..................... (REU-N2934W-US)
RU160e ..................... (REU-N2530W-US)
RU130e ..................... (REU-N2024W-US)
RUR199e ................... (REU-NP3237W-US)
RUR160e ................... (REU-NP2530W-US)
RESIDENTIAL
Commercial models are not cered for installaon in mobile
homes.
Certified to ANSI Z21.10.3 ● CSA 4.3
U334-1924(00)
1

Other manuals for Rinnai RU180i

Question and Answer IconNeed help?

Do you have a question about the Rinnai RU180i and is the answer not in the manual?

Rinnai RU180i Specifications

General IconGeneral
TypeTankless
Fuel TypeNatural Gas or Propane
Flow RateUp to 9.8 GPM
Weight56 lbs
Gas Connection3/4" NPT
Water Connection3/4" NPT
Heat ExchangerCopper
CategoryIndoor
Maximum Input BTU180, 000 BTU/h
Minimum BTU Input15, 000 BTU/h
Temperature Range98°F - 140°F
Vent TypeDirect Vent
Power Supply120V
Warranty5 years on parts