TROUBLESHOOTING GUIDE
3
The error codes indicate a failure or problem that must be rectified to guarantee the good function of the system
The error code and the water temperature are displayed alternately on the keypad
The error messages listed below display on the LCD and LED keypads If your spa is equipped with a color keypad,
please refer your techbook for more information on error messages
FLO
The system has detected no water flow during the main
pumps operation
UPL
No low-level configuration is present in the control system
memory, insert a valid instik to program the control unit
OH
The spas water temperature has reached 108°F (42°C)
Do not enter spa water!
AOH
The temperature inside the spa skirt is too high and
causes an increase of the internal temperature of the
control system above normal limits
Possible error codes on in.yj, in.ye, in.yt and in.xe control systems
Troubleshooting
HL
The water temperature in the water heater has reached
119 °F (48°C)
Do not enter spa water!
Prr
The system detects a problem with the regulation probe
The system constantly verifies if the temperatures read by
the probe are inside the normal limits
Hr
An internal error with the system hardware has been
detected