Do you have a question about the Rittal SK 3386.xxx and is the answer not in the manual?
Category | Refrigerator |
---|---|
Voltage | 230 V |
Frequency | 50/60 Hz |
Refrigerant | R134a |
Protection Class | IP 54 |
Protection category to IEC 60 529 | IP 54 |
Colour | RAL 7035 |
Ambient Temperature Range | +10°C |
Housing Material | Sheet steel |
Details two sets of instructions for the unit: paper document and PDF file on CD-ROM.
States that the declaration of conformity is supplied as a separate document.
Emphasizes that instructions and associated documents are integral parts of the product.
Explains symbols for instructed actions, danger, caution, and notes.
Provides essential safety guidelines for assembly, installation, operation, and maintenance of the unit.
Explains the purpose and basic working principle of the enclosure cooling unit.
Defines correct usage and highlights risks of improper operation or assembly.
Lists the items included in the delivery package for the cooling unit.
Provides guidelines for selecting an appropriate location for the enclosure cooling unit.
Details general assembly steps, including packaging checks and enclosure sealing.
Describes the procedure for mounting the cooling unit onto the enclosure roof.
Explains how to connect the condensate discharge hose, including routing requirements.
Covers essential electrical installation aspects, including connection data, safety, and wiring.
Details electrical connections like bus connection, serial interface, and power supply installation.
Details how to operate the cooling unit using the e-Comfort controller interface.
Lists supported voltage variants and key control functions of the e-Comfort controller.
Explains the energy-saving eco-mode and its activation/deactivation.
Describes how to activate a test function for the cooling unit's operation.
Provides guidance on changing parameters using buttons and the authorization code.
Lists and explains editable parameters for the cooling unit controller.
Illustrates the sequence of button presses for programming the controller parameters.
Explains how system messages are displayed and evaluated via relays.
Details how to configure master-slave relationships for multiple connected cooling units.
Describes how system messages are indicated and what actions to take.
Instructs on how to reset the controller after specific faults occur.
Discusses the maintenance-free design and general cleaning procedures for the cooling unit.
Provides detailed diagrams showing assembly dimensions and cut-out sizes for different unit models.