Cylinders must be stored outdoors out of the reach of children and must not be
stored in a building, garage or any other enclosed area.
1. Turn the burner valves off.
2. Turn the tank valve off fully (turn clockwise to stop).
3. Detach the regulator assembly from the tank valve by turning the quick coupling nut
counterclockwise.
CAUTION
When installing LP cylinders the pressure regulator and hose assembly supplied
with this grill must be used. Replacement pressure regulators and hose assemblies
must be those specified by the grill manufacturer.
Place dust cap on cylinder valve outlet whenever cylinder is not in use. Only install
the type of dust cap on the cylinder valve outlet that is provided with the cylinder
valve. Other types of caps or plugs may result in leakage of propane.
Although all gas connections on the grill are leak tested at the factory prior to shipment, a
complete gas tightness check must be performed at the installation site due to possible
mishandling in shipment, or excessive pressure unknowingly being applied to the unit.
Periodically check the whole system for leaks following the procedures listed below. If the
smell of gas is detected at anytime you should immediately check the entire system for
leaks.
BEFORE TESTING
Make sure that all packing material is removed from the grill including the burner
tie-down straps.
Make a soap solution of one part liquid detergent and one part water. You will need a
spray bottle, brush, or rag to apply the solution to the fittings. For the initial leak test,
make sure the LP cylinder is full.
WARNING
DO NOT SMOKE WHILE CONDUCTING LEAK TEST.
NEVER PERFORM LEAK TEST WITH AN OPEN FLAME.
If it is evident there is excessive abrasion or wear, or the hose is cut, it must be
replaced prior to the appliance being operational. The replacement hose shall be
specified the by manufacturer.
TO TEST
1. Make sure the control valves are in the “OFF” position,
and turn on the gas supply.
2. Check all connections from the gas cylinder, LP gas
regulator and supply valve up to and including all the
connections to the pipe that go to the burners (the
diagram shows the point where the soap water mixture