7.0StorageInstructions
7.1MP‐0130andMP‐6809ManualHydraulicPumpKit
Disconnectthehosefrompumpandplacethemetalplugintopumpport.Placetheplasticend
capsonthehoseendstoprotectthehoseendsfromdamage.
Checkthehydraulichoseforanydamageincludingbenthoseendsandsplitouterlining.Ifany
damageisfound,replacethehoseimmediatelybycontactingtheRiverhawkCompany.
Windthehydraulichosearoundthepumpandsecureinplacewiththehoseclamps.
Makesurethepumphasnotsufferedanyexternaldamageastheresultofimpacts,
mishandling,etc.
Cleanpumpandcheckthattherearenoexternalhydraulicoilleaks.Ifanyleaksareobserved,
contactRiverhawkforrepairoptions.
Lubricatethepump’smovingpartsbeforereturningthepumptostorage.
Placethehydraulicpumpkitintotheoriginalshippingcontainer.
7.2AP‐0532andAP‐6048Air‐DrivenHydraulicPumpKits
Disconnectthehosefrompumpandplacethemetalplugintopumpport.Placetheplasticend
capsonthehoseendstoprotectthehoseendsfromdamage.
Checkthehydraulichoseforanydamageincludingbenthoseendsandsplitouterlining.Ifany
damageisfound,replacethehoseimmediatelybycontactingtheRiverhawkCompany.
Windthehydraulichoseintoacirclenosmallerthan14"(360mm)indiameterandplaceinto
theoriginalshippingcontainer.
Makesurethepumphasnotsufferedanyexternaldamageastheresultofimpacts,
mishandling,etc.
Cleanpumpandcheckthattherearenoexternalhydraulicoilleaks.Ifanyleaksareobserved,
contactRiverhawkforrepairoptions.