EasyManua.ls Logo

Robertshaw 9801i2 User Manual

Robertshaw 9801i2
36 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Five Year Warranty
User's Manual
Menu Driven Display
Humidify / Dehumidify Control
Fully Programmable
Brighter / Adjustable Backlight
Night Light Option
Auto Changeover
Automatic Daylight Saving Time
24 VAC with
Worry-Free Memory Storage
English, Spanish or
French Display Option
110-1175
9801
i
2
9825
i
2
DELUXE
PROGRAMMABLE
THERMOSTATS
110-1175 English 7/17/06 1:59 PM Page 1

Other manuals for Robertshaw 9801i2

Question and Answer IconNeed help?

Do you have a question about the Robertshaw 9801i2 and is the answer not in the manual?

Robertshaw 9801i2 Specifications

General IconGeneral
Temperature Range45°F to 90°F (7°C to 32°C)
DisplayDigital
Stages1 Heat/1 Cool
Hold FeatureYes
BacklightNo
Battery LifeUp to 1 year
Power SourceBattery (2 x AA)

Summary

Robertshaw Programmable Thermostats User's Manual

Important Safety Information

Thermostat Controls and Displays Overview

Choosing Heating/Cooling Mode

Overriding Current Settings

Temporary Hold

Override temperature setpoint for up to 24 hours.

Vacation Hold

Override temperature setpoint for up to one year.

Overriding Fan Operation

Programming the Thermostat

EnergyStar® Recommended Setpoints

Preprogrammed setpoints for energy savings.

Schedule Menu Options

Navigate programming menus and events.

Setting Time and Date

Automatic Daylight Saving Time

Configure automatic DST adjustments.

Humidify Control Settings

Humidify Mode Options

Select humidification modes (Off, With Heating, Independent).

Humidify Setpoint and Adjustment

Set desired humidity and dew point adjustments.

Dehumidify Control Settings

Dehumidify Mode Options

Select dehumidification modes (Off, With Cooling, Independent).

Dehumidify Above Setting

Set preferred humidity levels for dehumidification.

Comfort Settings: Differentials and Sensors

Stage Differentials and Delay

Configure stage activation degrees and delays.

Sensor Configuration

Select thermostat or remote sensors.

Comfort Settings: Deadband and Recovery

Deadband Adjustment

Define range for heating/cooling switching.

Energy Efficient Recovery™ Explained

Feature for proactive setpoint achievement.

Customize Display: User Preferences

Temperature Display Settings

Units (°F/°C), resolution, and offset.

Language Selection

Choose display language (English, French, Spanish).

Customize Display: Service Reminders and Brightness

Air Quality Service Reminders

Set reminders for filter, bulb, humidifier pad.

Display Brightness and Contrast

Adjust screen backlight and clarity.

System Settings: Equipment Configuration

1st and 2nd Stage Equipment Setup

Configure heating/cooling stages and types.

Compressor Type and Fan Control

Define stage interaction and fan operation.

System Settings: Cycle Protection and Balance Points

Short Cycle Protection

Prevent compressor damage from short cycles.

Balance Points for Heat Pump

Optimize heat pump efficiency based on outdoor temp.

System Settings: Service Intervals and Temperature Limits

Setting Service Reminders

Configure maintenance alerts for system components.

Cooling and Heating Temperature Limits

Set maximum allowable temperatures.

System Settings: Auto Changeover and Defaults

Auto Changeover Feature

Automatically switch between heating and cooling.

Resetting System to Defaults

Restore factory settings for all parameters.

System Settings: Security Management

Enabling and Disabling System Security

Protect system settings with a PIN.

Prevent Thermostat Access

User Security Options

Control access to thermostat functions.

Technical Support Information

Frequently Asked Questions - Part 1

Understanding Balance Points

Explanation of balance points for heat pump operation.

Troubleshooting Flashing Display

Indicates time/date setup is required.

Frequently Asked Questions - Part 2

What is Deadband?

Range for heating/cooling switching control.

Energy Efficient Recovery™ Explained

Feature for proactive setpoint achievement.

Installer Settings Advisory

Warning against changing installer-configured settings.

Frequently Asked Questions - Part 3

Programming Daily Events

Options for 2, 4, or 6 daily program events.

Accessory Remote Indoor Sensors

Benefits and use of remote sensors.

Frequently Asked Questions - Part 4

Remote Outdoor Sensor Installation

Guidelines for installing outdoor sensors.

Time of Day Zoning with Sensors

Customizing temperature by time and location.

Faulty Sensor Behavior

Thermostat's response to sensor failure.

Frequently Asked Questions - Part 5

Resetting the Thermostat

Procedure to reset thermostat to factory defaults.

Identifying Heating/Cooling Status

How to tell if heating or cooling is active.

Five Year Limited Warranty

Related product manuals