Supplement POH DR400/120D, DR400/140B,
DR400/180R, DR400/200R, DR400/RP
Page 1 - 6 Issue 3 July 2014
FADEC-RESET
In case of a FADEC-warning, one or both FADEC warning lamps are
flashing. If then the "FADEC" Test Knob is pressed for at least 2
seconds:
a) the active warning lamps will extinguish if it was a LOW category
warning.
b) the active warning lamps will be illuminated steady if it was a
HIGH category warning.
CAUTION: If a FADEC-warning occurred, contact your
service center. Next flight is not permitted.
When a high category warning occurs the pilot should land as soon as
practical, since the affected FADEC ECU has diagnosed a severe fault.
A low category fault has no significant impact on engine operation.
Refer also to the engine manual OM-02-01 or OM-02-02 for additional
information.
FUELS, OILS and LIQUIDS
Approved fuels, oil and liquids are published in Section 2 - Limitations of
this POH Supplement.
WARNING: The engine must not be started if the oil or coolant level is
too low.
CAUTION: Use of unapproved fuels, oil and coolant may result in
damage to the engine and fuel system components,
resulting in possible engine failure.
CAUTION: Normally it is not necessary to fill the cooling liquid or
gearbox oil between maintenance intervals. If the level is
too low, please notify the service department
immediately.