EasyManua.ls Logo

Robin RGV7500 - Generator Specifications

Robin RGV7500
46 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Specifications are subject to change without notice.
*
: Electric starter model.
2. SPECIFICATIONS
4
MODEL RGV7500
Alternator
Type Brush, Self-Exciting, 2-Poles, Single Phase
Voltage regulator A.V.R type
Rated voltage 120 V/ 240 V
Maximum
output
7.3 kW
Rated output 6.0 kW
Rated power factor 1.0
Over current protector
No
-
fuse Breaker
Engine
Model
EH41D (EH41DS)*
Type Forced air-cooled, 4-cycle, Gasoline Engine
Displacement 404 cm
3
Fuel Automotive unleaded gasoline
Fuel tank capacity 7.26 US-gal (27.5 liter)
Rated continuous
operation (Approx.)
7.0 hours
Starting system Recoil (Electric starter)*
Dimension
Length
27.2 in. (690 mm) / 33.9 in. (860 mm) *
Width 20.9 in. (530 mm)
High 20.9 in. (530 mm)
Dry weight 198.4 lb (90 kg) / 209.4 lb (95 kg) *
60 Hz
60 Hz
60 Hz
DC output 12V
-
8.3A
60 Hz
Valve Clearance
(Intake & Exhaust)
0.0039
±
0.0012 in. (0.1
±
0.03 mm)
Note : Adjust the valve clearance while the engine is cold.
Emissions Durability Period
(California only)
500 hours
RGV7500RAi取説GU201805.4.41:24PMページ4