12
(f)Electric starter model
Insert the key into the key switch and
turn it clockwise to the "RUN" position
to start the engine.
Then turn the key further to the
"START" position. The engine will be
started by starting motor.
RUN
STOP
STOP
RUN
START
START
CHOKE LEVER
OPEN
CLOSE
Do not run the starting motor over 5 seconds continuously.
If the engine fails to start, return the key to the "RUN" position and wait
about 10 seconds then start again.
Do not turn the key switch to "START" when th engine is running to
prevent damage of starting motor.
Do not turn the key switch to "START" position when the engine is
running to prevent damage of starting motor.
When starting the engine by recoil starter, set the key switch at the "ON"
position and pull the starter handle.
CAUTION
(g) After the engine started, return the
choke lever gradually to "OPEN"
position.
(h) Warm up the engine without a load for
a few minutes.