11
PROBLEM
CAUSE
SOLUTION
3. Glass bleaching or colour
fading of the plate
Excessive temperature caused by excessive heat in
the combustion chamber
Check the fuel load avoiding overheating
Adjust registers
4. Poor heating Inappropriate fuel
Insufficient load
Combustion control registers in the wrong position
Use recommended fuel
Adding fuel
Adjust registers
5. Venting smoke and / or
gases from the front, bad
smell
First lighting
Flammable or combustible items in the enclosure or
surrounding walls of the equipment
Crack in the combustion chamber of the equipment
Wait for the polymerization process of the paint to finish;
this can take from one to several lightings.
Review of insulating materials such as fiberglass,
fireproof wood or any inflammable elements and replace
them.
Check for tightness and if you discover a crack, please
contact your dealer.
6. Excessive draft Incorrect duct
Combustion control registers in the wrong position
Duct servicing
- Excessive length (Install upper baffle plate following
steps "C.7", "C.8", "C.9", "C.10", "C.11", "C.12", "C.13"
and "C.14”)
- Check Depression
- Incorrect diameter
-
Check door gasket
7. Poor draft Incorrect duct
Duct dirtiness
Open the primary and secondary register following the
steps outlined in the manual. Should this not have an
effect, check that the flue duct is clean; if it is not clean,
contact a professional to clean this. If the problem persists
contact your dealer.
The CE label is located under the appliance. This label contains technical data and OF number. (This number can
also be found in the guarantee).
THIS NUMBER IS ESSENTIALFOR ORDERING SPARE PARTS.
7. CE INFORMATION
CAUTION:
- All tests are carried out in observance of Regulations
UNE-EN13240:2002-A2:2005-AC: 2006-A2:2005/AC: 2007 “Stoves that use solid fuels
Requirements and test methods”.
- The review of the equipment, the installation and ducts must
be carried out by a professional.
- In case of doubt regarding the described herein, please contact your Rocal dealer.
- FAILURE TO COMPLY WITH THE OBLIGATIONS DESCRIBED HEREIN OR IMPROPER HANDLING OF THE EQUIPMENT SHALL EXONERATE