Publication 2711P-UM001I-EN-P - December 2008 97
Configuration Mode Chapter 4
Start FactoryTalk View ME Station Software and Load .MER Application
To start FactoryTalk View ME Station software and automatically load
an .MER application, type the appropriate shortcut path in the Run
dialog on the Windows Start menu.
Path to MERuntime.exe, followed by a space, followed by the
path to the .MER
If the path to FactoryTalk View ME runtime or the path to the
application contains spaces, you must enclose the path in double
quotes.
If you place a shortcut to the .MER application into the Windows
Startup (\Storage Card\Windows\Startup) folder, the ME Runtime will
automatically start and load the .MER application on terminal startup.
If the application specified in the Run dialog or the Startup folder does
not exist or is corrupted, the main FactoryTalk View ME Configuration
Mode screen will open.
Start FactoryTalk View ME Station and Run .MER Application
To start FactoryTalk View ME Station software and automatically run
an .MER application:
in FactoryTalk View Studio software, select Tools>Transfer
Utility and select Run application when download completes on
the Download tab.
type the appropriate shortcut path in the Run dialog on the
Windows Start menu.
Path to MERuntime.exe, followed by a space, followed by the
path to the .MER, followed by /r
If the path to FactoryTalk View ME runtime or the path to the
application contains spaces, you must enclose the path in
double quotes.
If you place a shortcut with the above command line in the Windows
Startup folder (\Storage Card\Windows\Startup), the ME Runtime will
start and automatically run the .MER application.
If the application specified in the Run dialog or the Startup folder does
not exist or is corrupted, the main FactoryTalk View ME Configuration
Mode screen will open and display the following message:
Unable to load application
Example:
"Storage Card\Rockwell Software\RSViewME\MERuntime.exe" "Storage Card\Rockwell Software\RSViewME\Runtime\MYAPP.MER"
Example:
"Storage Card\Rockwell Software\RSViewME\MERuntime.exe" "Storage Card\Rockwell Software\RSViewME\Runtime\MYAPP.MER" /r

Table of Contents

Other manuals for Rockwell Automation PanelView Plus 1000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rockwell Automation PanelView Plus 1000 and is the answer not in the manual?

Rockwell Automation PanelView Plus 1000 Specifications

General IconGeneral
BrandRockwell Automation
ModelPanelView Plus 1000
CategoryTouch terminals
LanguageEnglish

Related product manuals