TLSZR/L-GD2
10000302608 Ver 00 July 2012 9
Minimum Operating Radius [mm (in.)]
Manual Override Key for Power-to-Release Version
80 (3.19) 80 (3.19) 80 (3.19) 80 (3.19)
Minimum operating radius is for all planes of approach of the actuator key, both along the
length and perpendicular to the key. Use the two adjusting setscrews on the actuator to
optimize the key angle.
The cover with manual override key is intended for use with a power-to-release version TLSZR-GD2.
It provides an auxiliary release function for use when power is not available to achieve automatic/electrical interlocking.
90°
1.2 N·m
(10.62 lb·in)
1