Remote control commands
R&S
®
RTA4000
715User Manual 1335.7898.02 ─ 08
Parameters:
<AnalysisType> OFF | QUALity | CONSumption | HARMonicsINRushcurrent |
RIPPle | SPECtrumSWITchingloss | SLEWrateMODulation |
DONResistance | EFFiciencySWITchingloss | TURNonoff |
TRANsient
*RST: OFF
POWer:AUToscale
Performs an autoset of the voltage and current source scales.
Usage: Event
POWer:AUToscale:CURRent
Performs an autoset of the current source scale.
Usage:
Event
POWer:AUToscale:VOLTage
Performs an autoset of the voltage source scale.
Usage:
Event
POWer:ENABle
Enables/disables the power analysis measurements.
Parameters:
<State> ON | OFF
*RST: OFF
POWer:RESult:TABLe
Displays or hides the result table.
The command is available for harmonic and spectrum power measurements.
Parameters:
<Visible> ON | OFF
*RST: OFF
POWer:SOURce:CURRent<n>
Sets the channel for the current source. Connect the current probe in flow direction of
the current.