Remote control commands
R&S
®
RTA4000
719User Manual 1335.7898.02 ─ 08
Return values:
<ApparentPower>
Usage: Query only
POWer:CONSumption:RESult:DURation?
Queries the duration of the measurement. The result is displayed in seconds.
Return values:
<Duration>
Usage: Query only
POWer:CONSumption:RESult:ENERgy?
Queries the energy.
Return values:
<Energy>
Usage: Query only
POWer:CONSumption:RESult:PFACtor?
Queries the power factor, a measure of the system efficiency. The value varies
between -1 and 1.
Return values:
<PowerFactor>
Usage: Query only
POWer:CONSumption:RESult:PHASe?
Queries the phase angle, the angle between the current and the voltage sine waves.
Return values:
<Phase>
Usage: Query only
POWer:CONSumption:RESult:REACtive?
Queries the reactive power, the power flow that is temporarily stored in a system
because of the inductive and capacitive elements.
Return values:
<ReactivePower>