INTRODUCTION TO NOVA II & NOVA IV
The NOVA II & IV have been designed for quick, easy installation in either of two levels. The Basic level is adopted by most users. The Advanced level of installation gives
additional facilities for locating the source of an alarm.
When should I use the Basic Installation Setup?
Use this simple setup when you have only one transmitter for each zone, or when you do have several transmitters per zone but do not have to identify them individually.
Program each zone on your panel, just as you do using wired sensors.
What are the advantages of Advanced Installation Setup?
With the NOVA II (NOVA IV) Advanced Installation, you can identify the source and the cause of any alarm from up to 8 (16) wireless detectors and portable devices, even
when you use only 2 (4) zones of your panel. The latch display will show you which transmitters alarmed during the previous ARM period. This is possible because the
connection of the NOVA II (NOVA IV) to the arm follow output of the panel allows the receiver to freeze all alarms that occurred while the system was armed.
Did you choose the Advanced Installation? If so, please proceed to page 2 having first familiarised yourself with the Preparation of the Receiver and the layout
diagram (Figure 1) below.
For more information, contact the ROKONET branch office nearest to you.
NOVA II & NOVA IV FEATURES
NOVA II
§ Processes radio signals from up to 8 remote transmitters including PIR and smoke detectors, universal/door/window-contact transmitters, wireless panic
buttons and remote controls.
§ Has 2 ZONE alarm outputs and a TROUBLE output that indicates low battery, tamper, dead transmitter or jamming.
NOVA IV
§ Processes radio signals from up to 16 remote transmitters including PIR and smoke detectors, universal/door/window-contact transmitters, wireless
panic buttons and remote controls.
§ Has 4 ZONE alarm outputs and a TROUBLE output that indicates low battery, tamper, dead transmitter or jamming.
NOVA II & NOVA IV
§ Memorize the pre-programmed identifying address of each transmitter during installation.
§ Outputs may be connected to any control panel.
PREPARATION OF NOVA II OR NOVA IV RECEIVER
Regardless of the chosen level of installation (basic or advanced), you should prepare your NOVA receiver as follows:
§ Remove the cover by inserting and twisting a screwdriver in the slots along the upper or lower edge of the receiver.
§ Mount the NOVA receiver high – at least 1.5 m (5 ft) above the floor near the control panel.
§ Mount the Receiver relatively close and central to the transmitters’ locations. Receiver should be kept away from metal objects and RF generating devices
such as TV sets and computers.
§ Connect the antenna to the left terminal of TB4 (see Fig. 1).
§ Set all positions on dip-switches SW1 and SW2 to OFF (levers are pushed DOWN).
LAYOUT AND WIRING OF NOVA II & NOVA IV
For the basic level of installation, it is assumed that you need Normally Closed inputs to your control panel.
The schematic drawing allows you to familiarize yourself with the different
elements you need for the installation.
TB4: Reserved for the antenna connection
SW1*: Micro-switch used for programming and testing options (see Table 2)
SW2**: Micro-switch used in advanced mode of installation (see Table 4)
S2: Switch used to “step” through the LEDs during addressing
S1: Tamper switch (used also to clear the transmitters addresses)
TX:
LEDs for identification and location of transmitters addresses
JP1:
Determines the supervision time for advanced mode
Figure 1: Circuit Board Layout
Notes:
Please note that the outputs are dry contacts. All outputs are Normally Closed.
The zone outputs may be set to Normally Open by setting dip-switch SW1 position 2 to ON.
See Table 2
Figure 2: Receiver Terminal Block to Control Panel Wiring Diagram
Question and Answer IconNeed help?

Do you have a question about the Rokonet NOVA II and is the answer not in the manual?

Rokonet NOVA II Specifications

General IconGeneral
BrandRokonet
ModelNOVA II
CategoryReceiver
LanguageEnglish

Summary

Installation Instructions and Operation Manual

Introduction to NOVA II & IV

Overview of basic vs. advanced installation levels for NOVA II and IV receivers.

NOVA II & NOVA IV Features

Details the capabilities and specifications of NOVA II and NOVA IV wireless receivers.

Preparation of NOVA II or NOVA IV Receiver

Steps for physically preparing the NOVA receiver before installation.

Layout and Wiring of NOVA II & NOVA IV

Diagrams and instructions for the physical layout and wiring connections.

Basic Level Installation & Operation

Registering Transmitter Addresses in Receiver

Step-by-step guide for pairing wireless transmitters with the receiver.

Communication Link Test

Procedure to test the RF transmission quality and signal strength.

Basic Level Operation Mode

Describes normal receiver operation and how signals are indicated.

Advanced Level Installation

Advanced Level Installation & Operation

Details specific to the advanced setup and operational features.

Transmitter Address Management

To Verify Set-Up

Procedure to check and display programmed transmitter settings.

Arm / Disarm Option - Zone 1 Only

Configuration for using Zone 1 to arm and disarm the receiver.

To Erase an Address from Receiver

Instructions for removing a transmitter from the receiver's memory.

Trouble Output Operation

Explanation of the trouble output and its relation to SW2 settings.

Normal Mode Operation Details

Describes receiver behavior during ARM and DISARM periods.

Event Retrieval and System Information

Event Retrieval From Memory

How to view recent events stored in the receiver's memory.

Application Questions & Answers

Addresses common queries regarding supervised transmitters and restorable devices.

Specifications

Technical specifications for the NOVA II & IV receivers.

Caution Notice

Important warnings regarding FCC compliance and potential interference.

Rokonet Limited Warranty

Details the warranty terms and conditions for Rokonet products.