Do you have a question about the Rolair GD4000PV5H and is the answer not in the manual?
Model | GD4000PV5H |
---|---|
Type | Portable |
Engine | Honda GX200 |
Horsepower | 5.5 HP |
Max Pressure | 135 PSI |
Power Source | Gasoline |
Inhaling compressed air may contain harmful substances.
Improper maintenance or modification of air tanks can cause explosion.
Improper grounding or wet conditions can lead to shock.
Sparks or flammable vapors near hot parts can cause ignition.
Contact with belts, pulleys, or fans can cause serious injury.
Touching hot engine or compressor parts can cause burns.
Lifting objects too heavy for one person can cause injury.
Debris propelled by air stream can cause eye injury.
Improper use or fatigue can lead to injury or death.
Improper transport or operation can cause leaks and damage.
Discharges tank pressure to prevent over-pressurization.
Protects motor from overheating by tripping a reset button.
Automatically starts/stops compressor based on tank pressure.
Adjusts and displays the output pressure for tools.
Measures tank or output pressure.
Allows moisture to be drained from the storage tank.
Prevents foreign matter from entering the pump or engine.
Manages compressor operation based on tank pressure settings.
Used to check and maintain the oil level in the pump.
Maintains tank pressure and aids loadless starts.
Vents crankcase pressure; must be in place for operation.
Reduces engine speed during idle periods on gas units.
Allows motor/pump to warm up before engaging pressure.
Unique system for maintaining proper belt tension on gas units.
Rubber pads protect the tank assembly from vibration.
Stops the engine quickly.
Assists in starting a cold engine.
Controls fuel flow to the engine.
Ensures proper oil submersion and prevents damage.
Ensures proper cooling and prevents air contamination.
Critical for pump lubrication and longevity.
Prevents premature wear caused by dirt ingestion.
Extension cords can cause voltage drop and affect performance.
Generators may not provide sufficient starting wattage.
Prevents vibration and premature failure.
Essential for preventing premature compressor failure.
Combats internal tank corrosion.
Instructions for starting and stopping electric direct-drive units.
Covers start/stop, constant-speed, and dual-control operation.
Allows switching between start/stop and continuous running.
Specifies continuous or intermittent operation limits.
Key engine controls and operational notes for gas units.
Impact of elevation on compressor performance and motor needs.
General tips for checking leaks, cleaning filters, and retorquing.
Guidance on checking and maintaining pump oil levels.
Daily, weekly, monthly, and quarterly checks.
Specific torque values for various pump components.
Instructions for adjusting pressure settings and fine-tuning.
Procedure for adjusting belt tension on gas units.
Importance of proper alignment and belt tension.