Roland GW-7 MIDI Implementation
MSB LSB MSB LSB Function and range
00H 05H mmH llH Modulation Depth Range
mm: 00H - 04H (0 - 4 semitones)
ll: 00H - 7FH (0 - 100 cents), 100/128 Cent/Value
7FH 7FH --- --- RPN null
Set condition where RPN and NRPN are unspecified. The
data entry messages after set RPN null will be ignored. (No
Data entry messages are required after RPN null). Settings
already made will not change.
mm, ll: ignored
Program Change
Status 2nd byte
CnH ppH
n = MIDI channel number: 0H - FH (ch.1 - 16)
pp = Program number: 00H - 7FH (prog.1 - prog.128)
* Not transmitted when System: Prog TxRx = OFF. (Initial value is ON)
Pitch Bend Change
Status 2nd byte 3rd byte
EnH llH mmH
n = MIDI channel number: 0H - FH (ch.1 - 16)
mm, ll = Pitch Bend value: 00 00H - 40 00H - 7F 7FH (-8192 - 0 - +8191)
* Not transmitted when System: P.Bend TxRx = OFF. (Initial value is ON)
System Realtime Messages
Timing Clock
Status
F8H
* Not transmitted when System: Clock Tx = OFF. (Initial value is ON)
Song/Style Start
Status
FAH
* Not transmitted when System: StartStop Tx = OFF. (Initial value is ON)
* This message is transmitted when the internal song/style player is started.
Song Continue
Status
FBH
* Not transmitted when System: StartStop Tx = OFF. (Initial value is ON)
* This message is transmitted when the internal song player is started not from the
beginning.
* Transmitted only in Song Mode.
Song/Style Stop
Status
FCH
* Not transmitted when System: StartStop Tx = OFF. (Initial value is ON)
* This message is transmitted when the internal song/style player is stopped.
Active Sensing
Status
FEH
* This message is transmitted constantly at intervals of approximately 250 msec.
System Common Message
Song Position Pointer
Status 2nd byte 3rd byte
F2H llH hhH
ll = song position LSB: 00H - 7FH
hh = song position MSB: 00H - 7FH
* Not transmitted when System: SongPos TxRx = OFF. (Initial value is ON)
* Transmitted only in Song Mode.
System Exclusive Messages
System Exclusive messages related to mode settings
These messages are used to initialize a device to GS or General MIDI mode, or change the
operating mode. When creating performance data, a “GM1 System On” message should be
inserted at the beginning of a General MIDI 1 score, a “GM2 System On” message at the
beginning of a General MIDI 2 score, and a “GS Reset” message at the beginning of a GS
music data. Each song should contain only one mode message as appropriate for the type of
data. (Do not insert two or more mode setting messages in a single song.) “GM System On”
uses Universal Non-realtime Message format. “GS Reset” uses Roland System Exclusive
format “Data Set 1 (DT1)”.
GM1 System On
Status Data byte Status
F0H 7EH, 7FH, 09H, 01H F7H
Byte Explanation
F0H Exclusive status
7EH ID number (Universal Non-realtime Message)
7FH Device ID (Broadcast)
09H Sub ID#1 (General MIDI Message)
01H Sub ID#2 (General MIDI 1 On)
F7H EOX (End Of Exclusive)
GM2 System On
Status Data byte Status
F0H 7EH, 7FH, 09H, 03H F7H
Byte Explanation
F0H Exclusive status
7EH ID number (Universal Non-realtime Message)
7FH Device ID (Broadcast)
09H Sub ID#1 (General MIDI Message)
03H Sub ID#2 (General MIDI 2 On)
F7H EOX (End Of Exclusive)
GM System Off
Status Data byte Status
F0H 7EH, 7FH, 09H, 02H F7H
Byte Explanation
F0H Exclusive status
7EH ID number (Universal Non-realtime Message)
7FH Device ID (Broadcast)
09H Sub ID#1 (General MIDI Message)
02H Sub ID#2 (General MIDI Off)
F7H EOX (End Of Exclusive)
GS Reset
Status Data byte Status
F0H 41H, dev, 42H, 12H, 40H, 00H, 7FH, 00H, 41H F7H
Byte Explanation
F0H Exclusive status
41H ID number (Roland)
dev Device ID (dev: 00H - 1FH (1 - 32), Initial value is 10H (17))
42H Model ID (GS)
12H Command ID (DT1)
40H Address MSB
00H Address
7FH Address LSB
00H Data (GS reset)
41H Checksum
F7H EOX (End Of Exclusive)