13
Jan. 2007 MV-8800
Checking the Version
Number
1. While holding down [SHUTDOWN], power-on the MV-8800.
The software version number and checksum are shown in the middle of
the screen.
Sys: Version number and checksum of the main system software
Boot: Version number and checksum of the updater and version
display software
Sub: Version number and checksum of the panel board sub-CPU
software
The version number and checksum are also shown in the screen when you
start up Test mode (TEST MODE TOP PAGE (FOR SERVICE) screen).
Saving and Loading Data
Here’s how to back up and restore the data on the hard disk.
Required Items
• Computer equipped with a USB connector
* You will need enough space to back up the contents of the MV-8800’s internal
hard disk.
• USB cable
Saving the Contents of the Hard
Disk onto Your Computer
1. Use a USB cable to connect your computer to the MV-8800.
2. Power-on the MV-8800.
3. Press [DISK/USB].
The DISK/USB MENU screen will appear.
4. Press [F3](USB).
The USB screen will appear.
5. Press [F5](Connect), and then press [F5](Yes).
The computer will detect the MV-8800’s internal hard disk.
6. Copy all files and folders from the root directory of the MV-8800’s
internal hard disk onto the hard disk of your computer.
Do not change the folder/file structure of the root folder.
7. On your computer, stop the USB connection.
8. Press [F5](Disconnect).
Loading the Saved Contents Back
Into the Hard Disk
1. Use a USB cable to connect your computer to the MV-8800.
2. Power-on the MV-8800.
3. Press [DISK/USB].
The DISK/USB MENU screen will appear.
4. Press [F3](USB).
The USB screen will appear.
5. Press [F5](Connect), and then press [F5](Yes).
The computer will detect the MV-8800’s internal hard disk.
6. Copy the folders/files saved on your computer’s hard disk to the root
folder of the MV-8800’s hard disk.
Do not change the folder/file structure of the root folder.
7. On your computer, stop the USB connection.
8. Press [F5](Disconnect).
Factory Reset Procedure
Here’s how to reset the system parameters to their factory-set state.
System parameters are saved on the internal hard disk, but this procedure will
reset all system parameters to their default values.
1. Power-on the MV-8800.
2. Press [SYSTEM].
The SYSTEM MENU screen will appear.
3. Press [F5](SysInfo).
The SYSTEM INFORMATION screen will appear.
4. Press [F3](Initialize), and then [F5](Yes).
All of the system parameters will be initialized to their factory-set state.
System Update Procedure
Updating from CD-ROM
Required Items
• MV-8800 (main unit and AC power cable)
• UPDATE CD-ROM (#17041842)